QUICK START GUIDE FOR DEMONSTRATION CIRCUITS 1071 

MAIN/CAM LED CONTROLLER 

LTC3210-2/LTC3210-3 

 

 

3

 

ENM Control – 

This vertical slide control ad-

justs the MAIN display from 0 to 20mA  in 32 

steps. This is accomplished by clicking on the 

up  or  down arrows  to  change  it  by one LSB, 

by  clicking  in  the  vertical  scroll  bar  to  incre-

ment  by  4  LSBs,  or  by  clicking  and  dragging 

the  slide  pointer.  The  individual  LED  current 

and the number of pulses required to achieve 

this current are displayed in the two text boxes 

below the slider. 

ENCT Control – 

This vertical slide control ad-

just  the  CAM  display  from  0  to  162mA  in  4 

steps.  The  current  is  limited  in  software  be-

cause some LEDs can not handle large con-

tinuous  currents.  The  LED  intensity  may  be 

adjusted by clicking on the up or down arrows 

to change it by one LSB, by clicking and drag-

ging the slide pointer, or by clicking in the ver-

tical scroll bar. The LED current and the num-

ber of pulses required to achieve this current 

are displayed in the two text boxes below the 

slider. 

ENCF  Control  – 

This  vertical  slide  control 

sets  the  CAM  display intensity during  a flash 

condition  from  0  to  378mA  in  8  steps. When 

the  FLASH  button  is  selected,  the  CAM  dis-

play  illuminates  at  the  intensity  set  by  the 

ENCF  control  on  the  release  of  the  mouse 

button  for  the  length  of  time  selected  in  the 

FLASH  TIME  drop-down  window.  The  LED 

flash intensity may be adjusted by clicking on 

the  up  or  down  arrows  to  change  it  by  one 

LSB,  by  clicking  and  dragging  the  slide 

pointer, or by clicking in the vertical scroll bar. 

The  LED  flash  current  and  the  number  of 

pulses  required  to  achieve  this  current  are 

displayed  in  the  two  text  boxes  below  the 

slider. 

FLASH Button –

 When this button is selected 

and  released,  the  CAM  LED  will  flash  at  the 

intensity  selected  in  the  ENCF  register  for  a 

period  selected  in  the  FLASH  TIME  drop-

down window. This is accomplished by reset-

ting  the  internal  counter  and  DAC  by  holding 

ENC  low  for  the  set  PULSE  TSD  time  then 

applying the set number of pulses on the ENC 

pin when the mouse button is released. After 

the flash time has elapsed, the CAM display is 

set back to the ENCT setting by holding ENC 

low for set PULSE TSD time then applying the 

set number of pulses on the ENC pin. 

FLASH  TIME  Drop-Down  Window  –

  This 

window allows the user to select a flash time 

from  50ms  to  1000ms  in  various  increments. 

The  flash  time  is  the  time  the  program  sets 

the  CAM  display  to  the  ENCF  setting  on  the 

release of the mouse button after the FLASH 

button was selected. 

PULSE TON Drop-Down Window –

 This win-

dow allows the user to select a pulse ON time 

for  the  ENM  and  ENC  pulses.  The  ON  time 

may  be  adjusted  from  5us  to  20us  in  5us  in-

crements.  

PULSE  TOFF  Drop-Down  Window  –

  This 

window allows the user to select a pulse OFF 

time  for  the  ENM  and  ENC  pulses. The  OFF 

time may be adjusted from 5us to 20us in 5us 

increments.  

PULSE TSD (RESET) Drop-Down Window –

 

This window allows the user to select a pulse 

TSD time for the ENM and ENC pulses. This 

is  the  time  the  ENM  and  ENC  pins  are  held 

low  to  reset  the  internal  counters  and  DACs 

prior to sending the pulses to the enable pins. 

This  time  may  be  adjusted  from  250us  to 

1000us in various increments.  

GRADATION  STEP  TIME  Drop-Down  Win-

dow  –

 This  window  allows  the  user  to  select 

the  length  of  time  for  each  gradation  step 

while  running  the  GRADATION  Cycle.  See 

GRADATION Cycle button for more details on 

this function. The gradation step time may be 

adjusted  from  50ms  to  250ms  in  various  in-

crements.  

UPDATE  Button  –

  When  this  button  is  se-

lected, the PIC is updated with the timing and 

ENM and ENC information, and the LED dis-