Linear Technology LTC3130EUD-1 Manual Download Page 4

4

dc2397af

DEMO MANUAL DC2397A

PARTS LIST

ITEM

QTY

REFERENCE

PART DESCRIPTION

MANUFACTURER/PART NUMBER

Required Circuit Components

1

3

C1, C5, C6

CAP CER 1µF 50V 10% X7R 0805

MURATA, GRM21BR71H105KA12L

2

1

C2

CAP CER 10µF 50V X7R 1210

MURATA, GRM32ER71H106KA12L

3

2

C7, C8

CAP CER 22µF 25V X7R 1210

MURATA, GRM32ER71E226KE15L 

4

2

C9, C10

CAP CER 0.1µF 50V X7R 0603

MURATA, GRM188R71H104KA93D

5

1

C11

CAP CER 4.7µF 6.3V 10% X5R 0603

MURATA, GRM188R60J475KE19D

6

1

C12

CAP CER 4.7µF 50V 10% X5R 0805

MURATA, GRM21BR61H475KE51L

7

3

R1, R2, R4

RES 2MΩ 1/16W 1% 0402 SMD

VISHAY, CRCW04022M00FKED

8

1

L1

INDUCTOR, 10µH, ±20% 

COILCRAFT, XAL4040-103ME

9

1

U1

25V, 600mA BUCK-BOOST DC/DC CONVERTER

LINEAR TECHNOLOGY, LTC3130UDC-1 #PBF

Additional Demo Board Circuit Components

10

0

C3, C14

CAP, 1210 (OPT)

11

0

C4

CAP ALUM 220μF 35V 20% SMD (OPT)

PANASONIC, EEE-FP1V221AP

12

0

C13

CAP, 0603 (OPT)

13

0

R3, R5, R6

RES, 0402 (OPT)

14

0

D1

DIODE SCHOTTKY 40V 2A SOD123 (OPT)

ROHM, RB068M-40TR

15

6

E1 – E6

TP, TURRET, 0.094", PBF

MILL-MAX, 2501-2-00-80-00-00-07-0

16

6

JP1 – JP6

JMP, 3-PIN 1 ROW 0.079" CC

SULLINS, NRPN031PAEN-RC

17

6

XJP1 – XJP6

SHUNT, 0.079" CENTER

SAMTEC, 2SN-BK-G

18

4

SPACER STACKING #4 SCREW NYLON 0.500"

KEYSTONE, 8833

Summary of Contents for LTC3130EUD-1

Page 1: ...ology the Linear logo and Burst Mode are registered trademarks of Linear Technology Corporation All other trademarks are the property of their respective owners PERFORMANCE SUMMARY Maximum power point control MPPC allows for simple optimization of power transfer between the converter and a non ideal supply such as a photovoltaic panel or anotherhighimpedancesource TheDC2397Ademoboard can be set to...

Page 2: ... FREQ JP2 VS1 VCC JP3 VS2 VCC JP4 MPPC OFF JP5 RUN ON JP6 EXTVCC INT 2 With power OFF connect the power supply PS1 as showninFigure4 Ifaccuratecurrentmeasurements are desired for efficiency calculation for example then connect ammeters in series with supplies as shown The ammeters are not required however 3 Connect a 50mA load 240Ω to VOUT as shown in Figure 4 4 Turn on PS1 and slowly increase the...

Page 3: ...397af DEMO MANUAL DC2397A Figure 3 DC2397A Thermal Performance VIN 12V VOUT 12V Load 600mA QUICK START PROCEDURE Figure 4 Proper Measurement Equipment Setup Figure 5 Measuring Input or Output Ripple GND VIN ...

Page 4: ...805 MURATA GRM21BR61H475KE51L 7 3 R1 R2 R4 RES 2MΩ 1 16W 1 0402 SMD VISHAY CRCW04022M00FKED 8 1 L1 INDUCTOR 10µH 20 COILCRAFT XAL4040 103ME 9 1 U1 25V 600mA BUCK BOOST DC DC CONVERTER LINEAR TECHNOLOGY LTC3130UDC 1 PBF Additional Demo Board Circuit Components 10 0 C3 C14 CAP 1210 OPT 11 0 C4 CAP ALUM 220μF 35V 20 SMD OPT PANASONIC EEE FP1V221AP 12 0 C13 CAP 0603 OPT 13 0 R3 R5 R6 RES 0402 OPT 14 0...

Page 5: ...TECHNOLOGY HAS MADE A BEST EFFORT TO DESIGN A CIRCUIT THAT MEETS CUSTOMER SUPPLIED SPECIFICATIONS HOWEVER IT REMAINS THE CUSTOMER S RESPONSIBILITY TO VERIFY PROPER AND RELIABLE OPERATION IN THE ACTUAL APPLICATION COMPONENT SUBSTITUTION AND PRINTED CIRCUIT BOARD LAYOUT MAY SIGNIFICANTLY AFFECT CIRCUIT PERFORMANCE OR RELIABILITY CONTACT LINEAR TECHNOLOGY APPLICATIONS ENGINEERING FOR ASSISTANCE THIS ...

Page 6: ...ORY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE EXCEPT TO THE EXTENT OF THIS INDEMNITY NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES The user assumes all responsibility and liability for proper and safe handling of the goods Further the user releases LTC from all claims arising from the handling or use of...

Page 7: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Analog Devices Inc DC2397A ...

Reviews: