background image

2

dc2458af

DEMO MANUAL DC2458A

QUICK START PROCEDURE

DC2458A is easy to set up to evaluate the performance 

of the LT8608. Refer to Figure 4 for proper measurement 

equipment setup and follow the procedure below:
NOTE: When measuring the input or output voltage ripple, 

care must be taken to avoid a long ground lead on the 

oscilloscope probe. See Figure 5 for the proper scope 

technique. 

1.  Set an input power supply that is capable of 42V/1.5A. 

Then turn off the supply.

2. With power off, connect the supply to the input 

terminals V

IN

 and GND.

3. Turn on the power at the input.
NOTE: Make sure that the input voltage never exceeds 

42V.
4. Check for the proper output voltage of 5V. Turn off 

the power at the input.

5. Once the proper output voltage is established, con-

nect a variable load capable of sinking 1.5A at 5V to 

the output terminals V

OUT

 and GND. Set the current 

for 0A.

a. If efficiency measurements are desired, an am-

meter can be put in series with the output load in 

order to measure the DC2458A’s output current.

b. A voltmeter can be placed across the output ter-

minals in order to get an accurate output voltage 

measurement.

6. Turn on the power at the input.

NOTE: If there is no output, temporarily disconnect 

the load to make sure that the load is not set too high.

7. Once the proper output voltage is established again, 

adjust the load and/or input within the operating range 

and observe the output voltage regulation, ripple 

voltage, efficiency and other desired parameters.

8. An external clock can be added to the SYNC termi-

nal when SYNC function is used (JP1 on the SYNC 

position). Please ensure that the chosen R

T

 sets the 

LT8608 switching frequency to equal or below the 

lowest SYNC frequency. See the data sheet section, 

Synchronization.

Figure 1. Efficiency vs Load Current at 2MHz Switching Frequency

I

OUT

 (A)

0

EFFICIENCY (%)

100

95

85

75

90

80

55

60

65

70

50

0.5

DC2458a F01

1.5

1

12V INPUT

24V INPUT

Summary of Contents for LT8608

Page 1: ...LTC LTM Linear Technology Burst Mode and the Linear logo are registered trademarks of Linear Technology Corporation All other trademarks are the property of their respective owners PERFORMANCE SUMMARY...

Page 2: ...he current for 0A a If efficiency measurements are desired an am meter can be put in series with the output load in order to measure the DC2458A s output current b A voltmeter can be placed across the...

Page 3: ...58af DEMO MANUAL DC2458A QUICK START PROCEDURE Figure 2 LT8608 Demo Circuit EMI Performance in CISPR25 Radiated Emission Test Antenna Polarization Vertical VIN 14V VOUT 5V IOUT 1 5A 2MHz Switching Fre...

Page 4: ...8af DEMO MANUAL DC2458A Figure 3 LT8608 Demo Circuit EMI Performance in CISPR25 Radiated Emission Test Antenna Polarization Horizontal VIN 14V VOUT 5V IOUT 1 5A 2MHz Switching Frequency QUICK START PR...

Page 5: ...5 dc2458af DEMO MANUAL DC2458A QUICK START PROCEDURE Figure 4 Proper Measurement Equipment Setup Figure 5 Measuring Output Ripple...

Page 6: ...6031M00FKEA 11 1 R5 RES CHIP 187k 1 10W 1 0603 VISHAY CRCW0603187KFKEA 12 1 U1 IC REGULATOR MSE10 LINEAR TECHNOLOGY LT8608EMSE PBF Additional Demo Board Circuit Components 1 1 C1 CAP ALUM 22 F 63V SUN...

Page 7: ...NLESS OTHERWISE SPECIFIED 1 ALL RESISTORS ARE 0603 SUNCON 63CE22BS 2MHz SYNC SPREAD SPECTRUM PULSE SKIPPING BURST VOUT VCC VCC E6 EN UV R2 18 2k E5 SYNC R4 1 00M C1 22 F 63V L1 2 2 H XFL4020 222MEC E9...

Page 8: ...RY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE EXCEPT TO THE EXTENT OF THIS INDEMNITY NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT SPECIAL INCIDENTAL...

Page 9: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Analog Devices Inc DC2458A...

Reviews: