background image

QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 763 

650MA STANDALONE LI-ION BATTERY CHARGER 

 

 

2

 

10mV of the preset voltage, at which time the 
charge current will begin to decrease. This is 
the  beginning  of  the  Constant  Voltage  mode 
of  the  charge  cycle.  Continue  to  slowly  in-
crease  the  battery  simulator  power  supply 
while  observing  the  CHRG  LED  to  go  out 
when  the  charge  current  drops  to  approxi-
mately  10%  of  the  programmed  charge  cur-
rent. 

7

After the timer has timed out, slowly decrease 
the  battery  simulator  power  supply.  At  ap-
proximately 4.1V, the charge current resumes 

and  a  new  charge  cycle  begins. 

This  is  the 

Recharge Threshold Voltage. 

 

8

To  verify  the  shutdown  mode,  move  jumper 
JP1  to  the  ‘‘OFF’’  position.  This  shuts  the 
charger down dropping the charge current to 
0mA.  

9

To verify battery drain current, remove the in-
put  supply  voltage.  The  ammeter  that  was 
reading charge current now reads the battery 
drain current. A typical value is less than 1µA.

 

.

 