background image

4

DC2277af

DEMO MANUAL DC2277A

‘System Tree’ View

‘Config’ View

‘Telemetry’ View

‘Idealized On/OFF Waveforms’  View

‘Chip Dashboard’
View

‘Quick Inspect’
View

‘Telemetry Plot’
View

Toolbar

Figure 4. LTpowerPlay Interface of Programming the LTC3886

Quick start proceDure

POWERING DOWN THE BOARD BETWEEN 

PROGRAMMING OPERATIONS

Disconnect the USB cable from the DC1427A/DC1613A 

before removing or inserting a LTC3886UKG into the 

programming socket.

WHAT YOU CAN DO WITH THE DC2277A

1.  Compare the contents of the EEPROM in the 

LTC3886UKG against your project or hex file.

2.  Reprogram the contents of the EEPROM in the 

LTC3886UKG using your project or hex file.

3.  Verify the EEPROM within the DC2277A contains the 

factory defaults. 

From the LTpowerPlay interface, load the factory 

defaults project file. This file is located at: 
C:\Program Files\Linear Technology\LTpowerPlay\

project files\ltc3886\datasheet_defaults.proj

Click the Verify button. 

Summary of Contents for DC2277A

Page 1: ...C3886 FEATURES n PMBus I2C compliant serial interface n Telemetry read back includes VIN IIN VOUT IOUT temperature and faults n Programmable voltage current limit digital soft start stop sequencing ma...

Page 2: ...r a vacuum suction device 4 Plug one end of the USB cable to your PC Plug other endofUSBcableintotheI2C SMBus PMBuscontroller 5 If you have a DC1427A plug the ribbon cable into J1 If you have a DC1613...

Page 3: ...3 DC2277af DEMO MANUAL DC2277A Quick Start Procedure Figure 3 DC1613A Ribbon Cable Installation...

Page 4: ...efore removing or inserting a LTC3886UKG into the programming socket WHAT YOU CAN DO WITH THE DC2277A 1 Compare the contents of the EEPROM in the LTC3886UKG against your project or hex file 2 Reprogra...

Page 5: ...R22 RES 100k 1 8W 1 0805 PANASONIC ERJ 6ENF1003V 14 1 R27 RES 0 499 1 8W 1 0805 STACKPOLE ELEC RMCF0805FTR499 15 3 R30 R34 R39 RES 1 1 8W 1 0805 PANASONIC ERJ 6RQF1R0V 16 3 R35 R36 R37 RES 4 99k 1 8W...

Page 6: ...ANTLY AFFECT CIRCUIT PERFORMANCE OR RELIABILITY CONTACT LINEAR TECHNOLOGY APPLICATIONS ENGINEERING FOR ASSISTANCE THIS CIRCUIT IS PROPRIETARY TO LINEAR TECHNOLOGY AND SCHEMATIC SUPPLIED FOR USE WITH L...

Page 7: ...GN A CIRCUIT THAT MEETS CUSTOMER SUPPLIED SPECIFICATIONS HOWEVER IT REMAINS THE CUSTOMER S RESPONSIBILITY TO VERIFY PROPER AND RELIABLE OPERATION IN THE ACTUAL APPLICATION COMPONENT SUBSTITUTION AND P...

Page 8: ...DING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE EXCEPT TO THE EXTENT OF THIS INDEMNITY NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONS...

Page 9: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Analog Devices Inc DC2277A...