4. The CSV file is ready to view. Go to “C:\Data-

Log6804_6811\” folder and open file.

2. A tab will appear on the left edge of the control panel 

for each board on the stack. Clicking on any of these 

tabs will transfer control commands and data to and 

from the display screen to that selected board.

3. Select whether the ADC’s Voltage Reference Powered 

State (Ref Up) and Over-/Undervoltage thresholds for 

each board are to be the same (GLOBAL) or different for 

each board (CUSTOM) and set the Ref Up and voltages 

accordingly.

COLOR CODED STATUS PANEL

The color-coded status panel will expand to include all 

boards connected in a stack. Each small square in this 

array represents an individual battery in the stack of 

boards. The intent of this display is to provide a way to 

see the status of all cells at a glance. The significance of 

the colors used is explained in the legend on the screen.
Consult the data sheet for detailed information concerning 

the operation of the LTC6811-2.

COMMANDS SUPPORTED (V05 VERSION):

POLLADC
WRITE CONFIG (REFUP, VUV, VOV, Discharge selected cells)
READ CONFIG
START CELL and OPEN WIRE conversions with and without 

discharge connected (ADC Settings: Conversion Mode, 

Open Wire Test Current)
READ CELL GROUPS (A, B, C and D. Read Volts/Hex)
START CONTINUOUS reads all cells every ~500ms.

COMMANDS NOT SUPPORTED (V05 VERSION):

SELFTEST
GPIO Logic Functions
READ FLAGS
READ AUX

OPERATING THE CONTROL SCREEN

5. View the CSV file in a compatible spreadsheet software 

program such as MS Excel.

SOFTWARE ADJUSTMENTS

The GUI program can control up to ten boards on a stack. 
1.  Select the number of boards on the stack by sliding the track 

bar up or down; located at the bottom left of the screen.

Summary of Contents for DC2260A

Page 1: ...tion 16 most positive potential L LT LTC LTM Linear Technology and the Linear logo and Linduino are registered trademarks and QuikEval is a trademark of Linear Technology Corporation All other trademarks are the property of their respective owners Photo 1 Connecting a Board to a PC Design files for this circuit board are available at http www linear com demo DC2260A Alternatively for a simple demo...

Page 2: ...2 dc2260af DEMO MANUAL DC2260A Photo 2 Connections and Jumpers DESCRIPTION ...

Page 3: ...3 dc2260af DEMO MANUAL DC2260A Figure 1 Simple Cell Simulator Using Resistors DESCRIPTION ...

Page 4: ... of all DC2260A ISOMD jumpers to the 1 position JP1 2 3 5 6 n Interconnection of isoSPI ports with RJ45 patch cables J3 and J4 are interchangeable n TERMinationjumpers JP11 onDC2260Ashouldallbe set to 0 except for the unit electrically furthest from the DC1941 JP11 set to 1 SOFTWARE SETUP To use the DC2026 USB interface board download the free driver for a program called QuikEval from http www lin...

Page 5: ...d 16 bit word to check that the data transmission was properly executed The received PEC15 word and the calculated PEC15 word from the received data are displayed in the top section labeled PACKET ERROR CODE 15 BIT and both words should match The oval located at the top of the color coded status panel for the one board will turn green if the PEC15 words match Data transmission errors will produce ...

Page 6: ...he six bytes read back should match the bytes sent and the PEC15 CRC15 check 16 bit words should be a match green PEC oval on stack display When any configuration information is changed on the screen the WRITE CONFIG command button will be il luminated serving as a reminder that this command still needs to be executed Set REFUP to 1 followed by a WRITE CONFIG command The Watchdog Timer WDT will no...

Page 7: ...e START OPEN WIRE command button connects the built in open wire detection circuitry to all cells This command must be followed by any command buttons inside the READ CELLS box click to see the result The OPEN WIRE TEST CURRENT box provides options to use either PULLUP or PULLDOWN Open Wire Test Currents An open wire connection to any cell will be indicated by an abnormally high voltage measuremen...

Page 8: ...ox with the label OFF means that the system is stopped and waiting for a new command to be sent DATALOGGING OPERATION The GUI program can datalog or store cell voltage re sults in a CSV Comma Separated Value csv file This feature is useful in characterizing cell voltages over time Dataloggingoperatessimilarlytocontinuousoperationbut has the added functionality of storing results in a CSV file 1 At...

Page 9: ...anel will expand to include all boards connected in a stack Each small square in this array represents an individual battery in the stack of boards The intent of this display is to provide a way to see the status of all cells at a glance The significance of the colors used is explained in the legend on the screen Consultthedatasheetfordetailedinformationconcerning the operation of the LTC6811 2 CO...

Page 10: ...TORY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE EXCEPT TO THE EXTENT OF THIS INDEMNITY NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES The user assumes all responsibility and liability for proper and safe handling of the goods Further the user releases LTC from all claims arising from the handling or use o...

Page 11: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Analog Devices Inc DC2260A ...

Reviews: