DEMO MANUAL DC2049A

QUICK START PROCEDURE

DC2049A is easy to set up to evaluate the performance of 

the LT3999EMSE. Refer to Figure 1 for proper measure-

ment equipment setup and follow the procedure below:
1.  Connect Load 1 (positive) between the VOUT1 and GND 

terminals and another Load 2 (negative) between the 

VOUT2 and GND terminals.

2.  With power off, connect the input power supply to the 

+VIN and –VIN terminals.

3.  Turn  the  input  power  supply  on  and  make  sure  the 

voltage is between 10V and 15.5V.

4.  To measure the output noise, connect one end of a BNC 

connector J1. Connect the other end of the BNC cable 

to an oscilloscope with a 50Ω input impedance. Refer 

to Application Note 70 for more precise techniques for 

measuring the output noise.

Figure 1. Test Procedure Setup Drawing for DC2049A

*J1 is the BNC connector to coaxial 

cable for noise measurement, please 

refer to AN70 Appendix B for details.