8
dc1978af
DEMO MANUAL DC1978A
FAULT SHARING SETUP IN THE GUI
Use the fault sharing setup tool to configure the fault
sharing in the GUI. Before doing so, view the fault sharing
demo in the GUI. Go to Tools > Fault Sharing Diagram.
Also, read the section on fault sharing in the data sheet.
“WHY AM I OFF?” TOOL
Use the “Why am I Off?” tool in the LTpowerPlay GUI to
diagnose the reason a power supply channel is turned off.
The tool can be located in the top right corner of the GUI,
next to the Register Information tab.
TRACKING BASED SEQUENCING
The LTC2974 supports tracking power supplies that are
equipped with a tracking pin and configured for tracking.
A tracking power supply uses a secondary feedback ter-
minal (TRACK) to allow its output voltage to be scaled to
an external master voltage. Typically, the external voltage
is generated by the supply with the highest voltage in the
system, which is fed to the slave track pins (see Figure 6).
Any supplies that track a master supply must be enabled
before the master supply comes up and disabled after the
master supply comes down. Enabling the slave supplies
COMMON DEMO BOARD OPERATIONS
Figure 4. Fault Sharing Utility in LTpowerPlay GUI
Figure 5. “Why am I Off?” tool in the LTpowerPlay GUI
DC1978a F04
DC1978a F05
Summary of Contents for DC1978A
Page 20: ...19 dc1978af DEMO MANUAL DC1978A DC1809A DETAILS BOTTOM...
Page 23: ...22 dc1978af DEMO MANUAL DC1978A DC1809A SCHEMATIC DIAGRAM...
Page 24: ...23 dc1978af DEMO MANUAL DC1978A DC1809A SCHEMATIC DIAGRAM...
Page 25: ...24 dc1978af DEMO MANUAL DC1978A DC1809A SCHEMATIC DIAGRAM...
Page 27: ...26 dc1978af DEMO MANUAL DC1978A DC1810A DETAILS BOTTOM...
Page 30: ...29 dc1978af DEMO MANUAL DC1978A DC1810A SCHEMATIC DIAGRAM...
Page 31: ...30 dc1978af DEMO MANUAL DC1978A DC1810A SCHEMATIC DIAGRAM...