background image

4

dc1886af

DEMO MANUAL DC1886A

Quick start proceDure

Inrush into capacitive load: One of the main functions of 

a hot swap circuit is to provide controlled ramp-up into a 

capacitive load to avoid disturbing the input power supply. 

For the following tests, ensure that the AUTORETRY jumper 

is set to OFF and the TIMER DURATION jumper is set to 

12ms. To guarantee that current limit is never reached 

during ramp-up into a capacitor, the current must be less 

than the minimum current limit threshold of 1.2A when 

the gate ramp rate is at its maximum value of 0.55V/ms. 

(Note that the minimum current limit threshold occurs 

when the FB pin is at zero.)
  C = I/(dV/dt) = 1.2A/(0.55V/ms) = 2182µF

Thus, the circuit will always power up successfully with a 

2000µF capacitor at V

OUT

, and observation of the TIMER 

turret post will show that it never begins to ramp. Figure 2 

shows successful ramp-up into a 1200µF capacitor. Inrush 

current is determined by ramp rate alone.
It is more complicated to find the smallest capacitor that is 

guaranteed to prevent successful ramp-up, since the cur-

rent into the load capacitor is a function of the scaled output 

voltage at the FB pin. As a starting point, the minimum 

ramp rate of 0.15V/ms should produce a current greater 

than the maximum current limit threshold of 1.8A (when 

FB is at zero) to ensure that the timer begins to ramp as 

soon as the output begins to rise.
  C = I/(dV/dt) = 1.8A/(0.15V/ms) = 12000µF

Figure 2. Successful Ramp-Up into 1200µF

I

OUT

1A/DIV

V

OUT

5V/DIV

TIMER

1V/DIV

Summary of Contents for DC1886A

Page 1: ...easily be evaluated Design files for this circuit board are available at http www linear com demo L LT LTC LTM Linear Technology and the Linear logo are registered trademarks and Hot Swap is a tradema...

Page 2: ...oper measurement equipment setup and follow the procedure below Demonstration Circuit 1886A has two user configurable jumper options JP1 TIMER DURATION Set to 2ms for the internal 2ms timer or 12ms de...

Page 3: ...nd the load current D2 and D4 should both be lit input voltage and output voltage respectively and both D3 FLT and D5 PG should be off On power up observe the slope of VOUT This should be in the range...

Page 4: ...ero C I dV dt 1 2A 0 55V ms 2182 F Thus the circuit will always power up successfully with a 2000 F capacitor at VOUT and observation of the TIMER turret post will show that it never begins to ramp Fi...

Page 5: ...final value The correct way to ensure successful power up into an output capacitance greater than 2000 F is to reduce the ramp rate by installing a 1k resistor and a suitable capacitor for RGATE and C...

Page 6: ...HOT SWAP CONTROLLER KIM T VLADIMIR O N A DEMO CIRCUIT 1886A SIZE DATE IC NO REV SHEET OF TITLE APPROVALS PCB DES APP ENG TECHNOLOGY Fax 408 434 0507 Milpitas CA 95035 Phone 408 432 1900 1630 McCarthy...

Page 7: ...DIODE 400W TRANSIENT VOLTAGE SUPPRESSOR SMA DIODE DIODES INC SMAJ22A 7 2 D2 D4 LED SMT GREEN PANASONIC LN1351C TR 8 2 D3 D5 LED SMT RED PANASONIC LN1251C TR 9 4 E1 E2 E3 E4 TURRET TEST PIN 094 MILL M...

Page 8: ...DING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE EXCEPT TO THE EXTENT OF THIS INDEMNITY NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONS...

Reviews: