DEMO MANUAL DC1877A

Quick start proceDure

This demonstration circuit 1877A can be evaluated using 

the setup shown in Figure 1. 
1. Connect the DVMs to the input and output. Select 5V 

setting using jumper JP1 (B position) and JP2 (A posi-

tion), select ON position for JP3. 

2. With input power supply set for 0V, connect the supply to 

V

IN

 and GND terminals using short (less than 10 inches) 

leads, preferably twisted leads. Connect a suitable load 

to V

OUT

 and GND terminals. 

3. Slowly increase the input power supply to 10V. Observe 

output voltage and verify that it meets the specifications 

in Table 1. Measure output voltage with and without the 

load. 

4. Move jumpers JP1 and JP2 to the other two fixed volt-

age settings and verify that each output voltage meets 

the values as shown in Table 1.

5. Once the proper output voltages are established, adjust 

the load and input voltage within the operating range 

and observe the output voltage regulation, ripple voltage 

and other parameters.

Notes:
1. IMPORTANT: 60V or higher voltage can result in an 

electric shock if care is not taken. Also, hot plugging 

the circuit to a power supply that has more than 40V 

present at its output can produce a high voltage transient 

exceeding the absolute maximum input voltage which 

can damage the LTC3630A. 

2. When measuring the input or output voltage ripple, 

care must be taken to avoid a long ground lead on the 

oscilloscope probe. Measure the input or output voltage 

ripple by touching the probe tip directly across the V

IN

 

or V

OUT

 and GND terminals. See Figure 2 for proper 

scope probe technique.

Figure 1. Proper Measurement Equipment Setup

Load

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.