DEMO MANUAL DC1736A

QUICK START PROCEDURE

Demonstration circuit 1736A is easy to set up to evalu-
ate the performance of the LT3975. Refer to Figure 2 for 
proper measurement equipment setup and follow the 
procedure below: 

NOTE. When measuring the input or output voltage ripple, 
care must be taken to avoid a long ground lead on the 
oscilloscope probe. Measure the input or output voltage 
ripple by touching the probe tip directly across the V

IN

 

or V

OUT

 and GND terminals. See Figure 3 for the proper 

scope technique.

1. Place JP1 on the ON position.

2. Place JP2 on the RT FREQ position.

3. With power off, connect the input power supply to V

IN

 

and GND. 

4. With power off, connect load from V

OUT

 to GND.

5. Turn on the power at the input. 

NOTE. Make sure that the input voltages do not exceed 42V. 

6. Check for the proper output voltage (3.3V).

NOTE. If there is no output, temporarily disconnect the load 
to make sure that the load is not set too high or is shorted.

7.  Once the proper output voltages are established, adjust 

the load within the operating ranges and observe the 
output voltage regulation, ripple voltage, efficiency and 
other parameters.

8. An external clock can be added to the SYNC terminal 

when SYNC function is used (JP2 on the SYNC posi-
tion). Please make sure that the SYNC frequency is at 
least 20% higher than the set switching frequency. See 
the data sheet section Synchronization.

LOAD CURRENT (A)

0

EFFICIENCY (%)

65

70

75

1.5

2.5

DC1735A F01

60

55

50

0.5

1

2

80

85

90

V

OUT

 = 3.3V

V

IN

 = 12V

f

SW

 = 600kHz

Figure 1. Efficiency vs Load Current