DEMO MANUAL DC1687A

Quick start proceDure

Using short twisted pair leads for any power connections 

and with all loads and power supplies off, refer to Figure 3 

for the proper measurement and equipment setup. The 

battery/power supply (PS1) should not be connected to 

the circuit until told to do so in the procedure below.
When measuring the input or output voltage ripple, care 

must be taken to avoid a long ground lead on the oscil-

loscope probe. Measure the input or output voltage ripple 

by touching the probe tip directly across the V

IN

 or V

OUT 

and GND terminals (see Figure 4), or by using an oscil-

loscope probe tip jack. 
1. Jumper and PS1 settings to start:
  PS1 = OFF 
  JP1 (PWM) = fixed frequency 
  JP2 (RUN) = ON   
2. With power OFF connect the power supply (PS1) as 

shown in Figure 3. If accurate current measurements 

are desired (for efficiency calculation for example) then 

connect an ammeter in series with the supply as shown.  

The ammeter is not required however.

3. Connect a 500mA load to V

OUT

 as shown in Figure 3 

(10Ω for V

OUT

 = 5V). Connect an ammeter if accurate 

current measurement or monitoring is desired. 

4. Turn on PS1 and slowly increase voltage until the volt-

age at V

IN

 is 4.0V.

5. Verify V

OUT

 is ~5.0V.

6. V

IN

 can now be varied between 2.7V and 40.0V. I

OUT

 may 

need to be reduced for V

IN 

< 4V. V

OUT

 should remain in 

regulation.

7. Load current (I

OUT

) can also be varied. The maximum 

I

OUT

 is a function of V

IN

 and the current limit. Consult 

the data sheet for more information on I

OUT

 vs V

IN

. In 

general for V

IN

 > 3.6V I

OUT

 can be increased to 1A. For 

V

IN

 > 6V I

OUT

 can be increased to 2A.

8. For operation in Burst Mode operation move Jumper 

JP1 to burst. I

OUT

 is limited in Burst Mode operation. 

See the data sheet for more information.

9. NOTE: If V

OUT

 drops out of regulation, check to be sure 

the maximum load has not been exceeded, or that V

IN

 

is not below the minimum value for regulation (see data 

sheet)

0

100

90

80

70

60

50

5

10

15

20

25

30

35

40

EFFICIENCY (%)

V

IN

 (V)

LOAD = 1A

LOAD = 500mA

0

100

90

80

70

60

50

5

10

15

20

25

30

35

40

EFFICIENCY (%)

V

IN

 (V)

LOAD = 300mA

LOAD = 200mA

LOAD = 100mA

Figure 1. DC1687A Efficiency in PWM Mode

Figure 2. DC1687A Efficiency in Burst Mode Operation