QUICK START GUIDE FOR DEMONSTRATION CIRCUIT 1317A-A
ACTIVE RESET ISOLATED 48V INPUT TO 3.3V @30A DC/DC POWER CONVERTER
5
by placing the associated components close to the
LT1952 and LT4430 chips.
Use local vias for all components that connect to
ground planes.
Do not place any traces on the layers 2 and n-1 to
avoid ground planes from being compromised.
If the PCB layout has to be done on 2 or 4-layer PCB
try to stay close to the guidelines outlined above. Also,
maximize the ground connections between compo-
nents by placing the components tight together.
Please contact LT factory for additional assistance.