Linear Technologie LTL.PL129IP25 Operation Manual Download Page 1

Linear Technologie • 11 rue du Puits Rochefort • 42 100 Saint-Etienne

 Tél: +33 (0)4 77 81 49 49 • Fax: +33 (0)4 77 81 49 40 • www.lineartech.fr

V.2017

LED PROJECTOR 12X9W
LTL.PL129IP25 / LTL.PL129IP45

Operation manual

Summary of Contents for LTL.PL129IP25

Page 1: ...inear Technologie 11 rue du Puits Rochefort 42 100 Saint Etienne T l 33 0 4 77 81 49 49 Fax 33 0 4 77 81 49 40 www lineartech fr V 2017 LED PROJECTOR 12X9W LTL PL129IP25 LTL PL129IP45 Operation manual...

Page 2: ...ns d Dimensions drawing e Exploded view f Photometric data g Safety warning 2 Installation a Mounting b Setting up with a DMX512 controller c Master slave operation 3 LED display panel operation a Bas...

Page 3: ...nels 5 modes intelligent ID addressing separately intelligent ID group addressing Display panel 4 LED digital display DMX address code test or play auto programs Advanced new function Set white balanc...

Page 4: ...atex circle 5 Heat sink 12 Display waterproof cover 6 Driving PCB 13 Fix screw knob 7 PCB fix plate 14 Bracket f Photometric data Red 960 472 240 116 50 Green 1450 720 345 160 76 Blue 260 132 64 32 15...

Page 5: ...kept clean and free of dust Always make sure that the power connections are connected correct and secure If there is any malfunction of the equipment contact LINEARLED immediately When transferring th...

Page 6: ...dresses should increase by increments of 9 e g 1 10 19 27 Each DMX address may be used as many times as required Any DMX address in the range from 001 to 511 may be used Each DMX address may carry up...

Page 7: ...8 programs 0 5 no function 5 36 program 1 37 68 program 2 69 100 program 3 101 132 program 4 133 164 program 5 165 196 program 6 197 228 program 7 229 255 program 8 CH8 Program fade in out time Progra...

Page 8: ...tput to 3 pin XLR plug or you can connect cables as following 3 pin XLR Pin 1 5 pin XLR pin 1 GND 3 pin XLR Pin 2 5 pin XLR pin 2 Negative signal 3 pin XLR Pin 3 5 pin XLR pin 3 Positive signal 5 pin...

Page 9: ...X S O F T S T A G A R C A R C D A R C S H S V S F O N S F O F d S 1 2 D 5 1 2 D 0 0 1 I D O f I D O N I D O O I D 5 0 M A S T S L A V A U T O A T 8 F A T 1 F A T 1 F A T 1 0 S P 0 1 T 0 0 1 S P 0 1 S...

Page 10: ...power fuse power cable connection Measure main voltage on the main connector Check connection of display PCB Replace a new display No responding to DMX controller Check a working mode setting on displ...

Page 11: ...cause greater accumulation of dirt on the fixture s optics Clean with soft cloth using normal glass cleaning fluid Always dry the parts carefully Clean the external optics at least every 20 days Clea...

Page 12: ...Linear Technologie 11 rue du Puits Rochefort 42 100 Saint Etienne T l 33 0 4 77 81 49 49 Fax 33 0 4 77 81 49 40 www lineartech fr...

Reviews: