6
5. CONNECTIONS
a. Speaker connections
Note :
Both the 4 - 16 ohms and 70V / 100V terminals cannot be used at the same time.
Impedances indicated in the figures represent the total speaker system (load) impedances.
WARNING
An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be
incorporated in the electrical installation of the building.
8. ~230V 50 Hz AC POWER INPUT
9. COMMON SPEAKER OUTPUT : Connectors for 4~16 ohms or 70V and 100V speaker.
10. LINE INPUT (XLR) : Music signal input balance.
11. LINE INPUT (6.35TRS) : Balanced or unbalanced input music signal (unbalanced input,
use of non-equilibrium 6.35TRS jack)
12. LINK OUTPUT (6.35TRS) : Balanced or unbalanced output music signal (unbalanced
output, use of non-equilibrium 6.35TRS jack)
13. LINE CASCADE OUTPUT (CORLEONE SOCKET) : XLR, output signal of power
amplifier.
14. FAN : Equipment, exhaust vents, equipment work properly, you must wrap the hole can
not have any object covered, to avoid overheating protection.
15. GROUND LIFTER : Earth line ground or lift switch. Enable the switch to “GND” position
when one unit is used, disable the switch “LIFT” when several units are used to avoid noise
caused by several earth line grounded.
4.2 Rear panel