background image

8

Operating instructions

Enable password lock

(KEY) (

ON

) / (

OFF

)

 {ENTER}

(

ON

)

 enable lock,

 (

OFF

)

 disable lock

Enable  the  password  lock,  control  panel  in  the  boot  or  go  into  standby  automatically  take 

effect, this time to operate lamps need to enter your password. { MODE, UP, MODE, DOWN, 

MODE,UP, MODE, DOWN } {ENTER}

DMX512 controller mode

1. Setting DMX512 address

(DMX) (

001--512

)

Access control panel function by pressing MODE until 

(DMX)

 is displayed.

Press ENTER, add or reduce channels by pressing UP/DOWN between 001 and 512.

Press MODE to exit.

2. Setting channels

(PERS) (11CH/04CH /06CH /15 CH /17 CH /21 CH /60 CH)

Access control panel function by pre ssing MODE until 

(PERS)

 is displayed.

Press ENTER button, select DMX channel by pressing UP/DOWN.

Press MODE to exit.

Main function

Subfunction

Selection

Instruction

PERS

11CH

Select 11/04/06/15/17/21/60 channel

setting

04CH
06CH
15CH
17CH
21CH
60CH

SET

d1M

OFF

«Off» means select linear dimming, or

choose dimmer 1-4 to control the 

dimming speed, dimming 1 of the fastest 

dimming curves, 4 for the most slowly 

dimming curve

DIM1/2/3/4

VER

Version number

KEY

ON ~ OFF

Enables or Disables password lockout

CoMP

C.SUM

01~16

Amount set of combined lights

C.id

01~16

Number set of combined lights

Summary of Contents for LTL.BL154

Page 1: ...Linear Technologie 11 rue du Puits Rochefort 42 100 Saint Etienne Tél 33 0 4 77 81 49 49 Fax 33 0 4 77 81 49 40 www lineartech fr V 2016 LED BAR 4 IN 1 LTL BL154 Operation manual ...

Page 2: ...2 TABLE OF CONTENTS Page 3 Page 4 Page 5 Page 7 Page 15 1 Before you begin 2 Introduction 3 Setup 4 Operating instructions 5 Appendix ...

Page 3: ...ore powering on the unit is to make sure the line voltage you are applying is within the range of accepted voltages This fixture will accommodate between 100V and 240V AC 50 60 Hz Each light is connected end to end by the power socket POWER IN and POWER OUT on the light or use the waterproof power cord Please ensure the head and the tail tightening when connect the lights to prevent the power leak...

Page 4: ... remodel the light randomly we will not take the guarantee for the faulty and damage which caused by dismantle repair or remodel of the nonprofessional person Maximum ambient temperature 40 C Do not operate fixture at temperatures higher than this Never connect the device to a dimmer pack Do not daisy chain power to more than 8 units 120V and 12 units 230V 2 INTRODUCTION Specifications Voltage rat...

Page 5: ...ht when installing it You must use the exclusive clamp hanger and screw when hanging it and make sure the weight of the light is within limits of the hanger Please make sure without any flammable objects within 0 5m when installing the light The installation should be operated by professional person any irregular installation will cause the body injury or equipment damage Block access below the wo...

Page 6: ...ch will have a male 3 pin connector to the input connector of the next fixture consisting of a female 3 pin connector Then proceed to connect from the output as stated above to the input of the following fixture and so on 3 This product can be connected numerous lamps in series without the need for the signal amplifier the signal will not be weakened 3 PIN to 5 PIN conversion chart Note If you use...

Page 7: ...unction Up Navigates upwards through the menu list and increases the numeric value when in a function Down Navigates downwards through the menu list and decreases the numeric value when in a function Menu map Main function Subfunction Selection Instruction DMX d001 001 512 Set DMX start address Colo R000 000 255 0 100 User can combine red green blue and white to generate a custom color G000 b000 W...

Page 8: ...ess MODE to exit 2 Setting channels PERS 11CH 04CH 06CH 15 CH 17 CH 21 CH 60 CH Access control panel function by pre ssing MODE until PERS is displayed Press ENTER button select DMX channel by pressing UP DOWN Press MODE to exit Main function Subfunction Selection Instruction PERS 11CH Select 11 04 06 15 17 21 60 channel setting 04CH 06CH 15CH 17CH 21CH 60CH SET d1M OFF Off means select linear dim...

Page 9: ...iption 1 LED 000 015 No function 2 LED 016 031 R 3 LED 032 047 G 4 LED 048 063 B 5 LED 064 079 R G 6 LED 080 095 G B 7 LED 096 111 R B 8 LED 112 127 R G B 9 LED 128 143 W 10 LED 144 159 R W 11 LED 160 175 G W 12 LED 176 191 B W 13 LED 192 207 R G W 14 LED 208 223 G B W 15 LED 224 239 R B W 240 255 R G B W 6 channels Channel Value Description 1 000 255 Red 2 000 255 Green 3 000 255 Blue 4 000 255 W...

Page 10: ... B W 16 Strobe 000 255 Strobe 0 20HZ 17 Fade 000 255 Dimmer speed fast to slow 11 channels Channel Value Description 1 Dimming 000 255 0 100 2 Red 000 255 0 100 3 Green 000 255 0 100 4 Blue 000 255 0 100 5 White 000 255 0 100 6 Macro color control 000 009 No function 010 255 Macro color control 7 Strobe 000 255 Strobe 00 20Hz 8 Module selection 000 004 1 ON 2 ON 3 ON 005 034 1 ON 035 064 2 ON 065 ...

Page 11: ...s priority over channels 2 3 4 5 Speed of the strobe is adjustable from 0 to 20 Hz Module selection Channel 8 provides individual control of the three LED modules in each fixture 245 255 switch to the 11CH 2 mode Auto programs Chanel 9 selects the preset auto programs 1 50 When activating the auto programs then it is possible to control the auto speed by using channel 10 Channel 9 has priority ove...

Page 12: ...ule 1 000 005 No function 17 Module 2 18 Module 3 006 255 Strobe 0 20HZ 19 Module 1 fade 000 255 Dimmer speed 20 Module 2 fade 000 255 Dimmer speed 21 Module 3 fade 000 255 Dimmer speed Attention Module 1 is composed of 1 5 LED Module 2 is composed of 6 10 LED Module 3 is composed of 11 15 LED 60 channels Channel Value Description 1 LED 1 000 255 Red 0 100 2 LED 1 000 255 Green 0 100 3 LED 1 000 2...

Page 13: ...l panel function by pressing MODE until COMP is displayed Press ENTER select C SUM by pressing UP DOWN buttons Press ENTER amount set of combined lights by pressing UP DOWN between 01 and 16 Press MODE to exit 2 Number set of combined lights Access control panel function by pressing MODE until COMP is displayed Press ENTER select C ID by pressing UP DOWN buttons Press ENTER Amount set of combined ...

Page 14: ... function 006 255 Strobe 0 20HZ 5 000 005 No function 006 255 Combine auto program AP 1 50 6 000 009 No function 010 255 Combine cartoon effects CP 1 25 7 000 255 No function 8 Mode selection 000 244 Convert to 11CH 1 245 255 Convert to 11CH 2 9 000 005 No function 006 255 AUTO AT 1 50 10 000 255 CH5 6 9 auto speed 11 000 255 Dimmer speed 4 Setting slave machine Access control panel function by pr...

Page 15: ...is does not mean that all of the LEDs have failed but the circuit is wired in series An LED may have failed resulting in a short circuit In this event only the single LED which has failed will no longer function This does not mean that all of the LEDs have failed but the circuit is wired in series Note In the event of LED failure a replacement LED PCB assembly may be purchased directly from our co...

Page 16: ...nnector is firmly connected to device This fixture must be in the correct mode in order to properly respond to the COLOR CON controller The correct mode is DMX in the onboard control panel Stand alone operation This fixture has built in automatic programs that may be triggered from the onboard control board The display is only showing The password lockout has been enabled You can use the password ...

Page 17: ...Linear Technologie 11 rue du Puits Rochefort 42 100 Saint Etienne Tél 33 0 4 77 81 49 49 Fax 33 0 4 77 81 49 40 www lineartech fr ...

Reviews: