background image

 

Input and Output Routing 

 

Initial I/O Setup 

 

Once logged in, click on the 

I/O menu

 (4A). Choose between SDI/AES-3/MADI or 

AES67 inputs and outputs in the 

Workflow menu

 (4B). Select between viewing 

Program (processed) and Passthrough (unprocessed) routing with the 

Program/Passthrough switch 

(4C). 

 

 

Figure 4:  I/O menu

 

 

Routing audio into the LA-5300 is a two-step process. The first step is 

creating an 

input group

 from the available physical hardware inputs. The second step is 

routing the audio from these inputs to the program (processor) input.

   

Creating an Input Group 

 
Click on your first 

audio input source

 (5A) to highlight it, then right click and select 

“Create Input Group.” 

 You may enter a custom name for this source in the 

Label 

field 

(5C) and 

customize the color

 of the graphical routing lines (5B).  

 
Click the 

Save button

 (5D) to save the configuration or the 

Cancel button 

(5E) if 

you need to start over without saving your configuration.  

 

Summary of Contents for LA-5300

Page 1: ...single 1RU solution for audio loudness control upmixing AC 4 decoding for watermarking bitstream analysis and monitoring transcoding of Dolby Digital and Dolby Digital Plus sources to AC 4 as well as...

Page 2: ...nt panel 1A Four status LEDs indicating the status of each power supply 1B 1C the overall status of the unit 1D and sync for the reference clock 1E A color LCD display to show status and basic configu...

Page 3: ...and one for AES67 I O 2B Two independent 3Gb s HD SD SDI inputs and outputs 2C on female BNC connectors Quad Link SDI or MADI I O 2D optional Five AES 3 I O connections 2E on female BNC connectors Pa...

Page 4: ...equipped with adequate surge protection and fitted with an uninterruptable power supply UPS Boot Up and Splash Screen The unit will power up as soon as the power cords are connected and using the Rese...

Page 5: ...Down button to navigate to the Netmask field following the instructions above for entering the value When finished editing the Netmask field press the Right Left buttons to highlight Netmask again Pre...

Page 6: ...hould be on the same network and subnet as the LA 5300 Once both LA 5300 and your computer are connected to your network enter the IP address of the LA 5300 in the URL field of your browser Once conne...

Page 7: ...first step is creating an input group from the available physical hardware inputs The second step is routing the audio from these inputs to the program processor input Creating an Input Group Click o...

Page 8: ...first set the priority of the input source by dragging the input audio lines 6A and then clicking when the desired priority level 6B is highlighted The LA 5300 will look for audio first on inputs con...

Page 9: ...Edit rectangle 8A Figure 8 Editing or deleting input group Creating an Output Group The steps for creating an output group are identical to creating an input group but with the Outputs menu Routing Au...

Page 10: ...a VRef clock source 9E The status of the selected Primary and Secondary Reference Clocks is shown to the right of the dropdown menu 9D The status of the clock is shown for each input 9B along with the...

Page 11: ...olby AC 4 encoding upmixing Nielsen and Verance watermark encoding and monitoring are found in the Program 1 menu Input metering 10A and output metering 10B for all channels and all I O is also locate...

Page 12: ...Click on the AC 4 Encoder dropdown menu 11A Choose the appropriate Channel Mode 11B Frame Rate 11C Bit Rate 11G Type 11F Loudness Regulation standard 11E and Language 11D for your application Figure...

Page 13: ...tically upmixed Unless the channel format of your incoming content is always the same we strongly recommend leaving this control set to Auto Detect to avoid unpredictable and unexpected results Use th...

Page 14: ...menu 13B to enable disable Nielsen watermarking Choose the appropriate process for your application in the Active Process dropdown menu 13A Click on the SID Check Digit CSID and or CBET Check Digit f...

Page 15: ...Enable dropdown menu 14B to enable disable Verance watermarking and the Calibrate dropdown menu 14A to enable disable the calibration mode Click on the Server Code and Interval Code fields 14D to ent...

Page 16: ...hannel Mode dropdown menu 15B to choose a 5 1 channel output or a Lo Ro or Lt Rt downmix The Target Reference Level dropdown menu 15A sets the decoded monitor output level The DRC Enable dropdown menu...

Page 17: ...TION HAZARDOUS VOLTAGES The instrument power supply incorporates an internal fuse Hazardous voltages may still be present on some of the primary parts even when the fuse has blown If fuse replacement...

Page 18: ...ccur if other devices are connected to this device without the use of shielded interconnect cables FCC rules require the use of shielded cables CANADA WARNING This digital apparatus does not exceed th...

Page 19: ...e updates from time to time by visiting our website or by contacting us directly Feedback We welcome feedback on any aspect of our products or this manual In the past many good ideas from users have m...

Page 20: ...authorization may be refused US customers please contact Telos Alliance Technical Support at 1 216 622 0247 All other customers should contact local representative to make arrangements for service Wa...

Reviews: