ATTENTION

 

 

ATTENTION

 

Do  not  power the  unit  on  when  using 
insecticide in the room

 

Otherwise the insecticide may be stored in 
the unit and will blow out during the normal 
working time.It is harmful to the health.

 

Please  ventilate  completely  after  having 
used the insecticide before turn on the unit.

 

 
 
 
 
 
 

Do not use in the room with 
lampblack such as kitchen.

 

It may cause hurt because the 
machine is not a ventilator

 

 
 
 
 
 
 

Do not blow in any combustible 
or fired cigarette into the unit.

 

It may cause fire

 

 
 
 
 
 
 

Do not use in the watery or high 
temperature room such as the 
bathroom etc.

 

Otherwise it may cause creepage, 
electric shocking or fire.

 

PRODUCT PERFORMANCE AND TECHNICAL FEATURES

 

Product performance

 

● 

Filtro antimicrobiano: Elimina  el moho, alergénos  y bacterias.

 

● 

HEPA

fabricado con una nueva generación de materiales, elimina eficazmente partículas  dañinas

 

● 

Carbón activado: una fabricación de alta tecnología en la biosíntesis de cascara de nuez en carbón y un área mayor, cran una mayor 

capacidad de adsorción de partículas y  humo.

 

● 

Foto catalizador: creado con dióxido de titanio tiene como  función dañar a las bacterias e inhibir la actividad de los virus.

 

● 

Anión: La gran cantidad de iones negativos generados, purifica y desinfecta el aire eliminando bacterias, hongos, alérgenos,  virus y malos 

olores. 

 

FORBID

 

 

Keep away from alcohol,organic 
impregnant or insecticide

 

It may cause cracking,short circuit, electric 
shocking, hurt or fire

 

Please ventilate timely when 
used with fire in the room

 

Otherwise it may cause poisoning 
of Co

as the machine is not a 

ventilator

 

Please hold the plug instead of 
the cord when unplug the power.

 

Otherwise it may cause short circuit, 
breaking of the cord,electric shocking 
or fire.

 

Please remove the plug from the 
socket if any conditions as below:

 

● 

If all switches do not work

 

● 

If the power cord or plug hot 

singularly

 

● 

If any peculiar smell, exceptional 

noise or vibration

 

● 

Any other abnormality or failure

 

 

 

Technical features

 

● 

Panel digital.

 

● 

Pantalla LED

 

● 

Alarma automatic para el cambio de los  filtros

 

● 

Diseño ERP c o n s u m o e n r e p o s o 

≤0.5W .

 

● 

Motor de ahorro de energía, más silencioso y  ecológico.

 

 

If the power cord is damaged, please send it to the retailer or service center or technician for repairing. Do not change or repair it by yourself.

 

Summary of Contents for RUBY PURE75

Page 1: ...en jugar con el purificador Los trabajos de limpieza y mantenimiento no deben ser realizados por ni os sin supervisi n Si el cable de alimentaci n estuviese da ado deber ser sustituido por el fabrican...

Page 2: ...para cambio de filtro 12 Anti bacterias Recude la cantidad de virus y su propagaci n La luz UV elimina las bacterias de manera eficiente e inhibe la activaci n de los virus COMPONENTES Exterior Interi...

Page 3: ...om the supply mains before cleaning or other maintenance Otherwise the unit may start working in a sudden which may cause electrical shocking or hurt Do not insert any metal objects into the unit It m...

Page 4: ...zador creado con di xido de titanio tiene como funci n da ar a las bacterias e inhibir la actividad de los virus Ani n La gran cantidad de iones negativos generados purifica y desinfecta el aire elimi...

Page 5: ...Lateral derecho Operating parts Diagram of operating button COMPONENT INTRODUCTION Interior Encendio apagado Velocidad Temporizador Funciones Cubierta izquierda Cuerpo Carb n activado foto catalizado...

Page 6: ...oto catalyst filter Power supply AC voltage Install Antimicrobial HEPA Lift up the unit with one hand and open the side cover with another hand by holding up from the bottom of the cover side cover in...

Page 7: ...seconds after a sound like D then enter children lock mode Pleae note the other button doesn t work under children lock mode Hold on power icon for 5 seconds again to quit children lock mode and other...

Page 8: ...place new filter 2 When speed indictor still flashing after a new filter replaced press time setting button and hold on for 5 seconds after a sound like D speed indictor will stop flashing and the mac...

Page 9: ...nment Notes air should be purified continuously Suggesting to ventilate then start up the machine Does the using life time for activated carbon filter come to the end Please replace new filters High n...

Page 10: ...time Antimicrobial HEPA 209 x 10 2 x 40 mm About 6 months Activated carbon and photo catalyst 203 x 97 x15 mm About 6 months Model No PURE 75 Voltage Supply 220V 240V 50Hz Air flow volume m 3 h 70m 3...

Page 11: ...ion If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard RUBY PURE 75 Intelligent air purifier Sedative Ser...

Page 12: ...hnical features COMPONENT INTRODUCTION Diagram of the outlook Diagram of unit Operating parts 4 4 5 6 5 5 6 Function setting 11 Filter replacement reminder 12 MAINTENANCE AND CLEANING INSTRUCTION 13 M...

Page 13: ...the supply mains before cleaning or other maintenance Otherwise the unit may start working in a sudden which may cause electrical shocking or hurt Do not insert any metal objects into the unit It may...

Page 14: ...the filter captured the cell membrane of bacteria inhibit virus activity Anion Negative ion is praised as Air Vitamin People live in the high negative ionic environment can promote human new and old s...

Page 15: ...DUCTION Touch control panel Front cover Back cover Air in Front cover Side cover Diagram of unit Front view Left view Right view Power Speed Timer Function Left cover Body Activated carbon photo catal...

Page 16: ...oto catalyst filter Power supply AC voltage Install Antimicrobial HEPA Lift up the unit with one hand and open the side cover with another hand by holding up from the bottom of the cover side cover in...

Page 17: ...seconds after a sound like D then enter children lock mode Pleae note the other button doesn t work under children lock mode Hold on power icon for 5 seconds again to quit children lock mode and other...

Page 18: ...place new filter 2 When speed indictor still flashing after a new filter replaced press time setting button and hold on for 5 seconds after a sound like D speed indictor will stop flashing and the mac...

Page 19: ...he detergent before use Benzene Acohol Maintenance and cleaning instruction Please remove plug from the socket before cleaning and maintenance Abnormal occurrence Checking methods Solution Do not work...

Page 20: ...e time Antimicrobial HEPA 209 x 102 x 40 mm About 6 months Activated carbon and photo catalyst 203 x 97 x15 mm About 6 months Model No PURE 75 Voltage Supply 220V 240V 50Hz Air flow volume m 3 h 70m 3...