SAFETY DEVICES
· This heater is protected with an overheat protection that switches off the heater automatically in case
of overheat, e.g. due to the total or partial obstruction of the grids. The overheating shut-off switches
off the temperature inside when the appliance exceeds the normal running temperature. The heating
element will automatically stop working, the motor will continue to operate, the internal heat shed.
This protective device applies only to the appliance itself and has no influence on room temperature
regulation. In this case, unplug the appliance, wait about 10 minutes for it to cool and remove the
object that is obstructing the grids. Then switch it back on as described above. The appliance should
operate normally. Should the problem persist, please contact the nearest customer service.
· The appliance is also equipped with a tip-over safety, which is integrated in the appliance. The
appliance will turn off when it tips over.
CLEANING AND MAINTENANCE
· Before cleaning the appliance, ensure it is disconnected from the power supply and has cooled down
completely.
· To avoid the risk of electric shock, do not clean the heater with
water and do not immerse it. Clean the housing with a damp
cloth.
· If necessary, dust particles accumulated in the air outlet
openings may be removed with a vacuum cleaner. This
maintenance should be done regularly to assure the good
operation of the appliance. Dust particles in the appliance may
cause over-heating.
· Store the appliance in a clean and dry place.
SPECIFICATIONS
Model identifier(s):
Item
Symbol
Value
Unit
Item
Unit
Heat output
Type of heat input, for electric storage
local space heaters only
Nominal heat output
Pnom
2,5
kW
manual heat charge control,
with integrated thermostat
No
Minimum heat output
(indicative)
Pmin
1,5
kW
manual heat charge control
with room and/or outdoor
temperature feedback
No
Maximum continuous
heat output
Pmax,c
2,5
kW
electronic heat charge control
with room and/or outdoor
temperature feedback
No
Auxiliary electricity
consumption
--
--
--
fan assisted heat output
No
At nominal heat
output
elmax
2,483
kW