background image

Приложение

 

Е48 серия

 

Тип с блокировкой клавиш

  

E48-111K,E48-112K,

 

 

Тип открытый коллектор

Appendix

 

E48 Series  Key Protect Type 

E48-211K,E48-311K

 

 

Open-collector output

This manual was last revised on Feb. 27,2012.

*Subject to change without prior notice.

All Rights Reserved, Copyright

©2012,LINE SEIKI CO.,LTD.

Цифры

PRESET LEVELS

INPUT

100mm

64mm

6

Переменный

ток 100-240 В

Переменный 

ток 100-240 В

Постоянный 

ток 12-24 В

100mm

Модели

IN A IN B 12V GND RES

5

4

3

2

6

11

1

7

8

9

10

12

OUT

C

E

GND RES

IN A IN B

5

4

3

8

9

10

12

2

6

11

1

7

OUT

C

E

RES

12V

IN B

IN A

GND

12

10

9

8

7

1

11

6

2

3

4

5

OUT 1

E

C

OUT 2

E

C

RES

12V

IN B

IN A

GND

12

10

9

8

7

1

11

6

2

3

4

5

PW

E

C

OUT

C

E

OUTPUT

Выход

OUTPUT DELAY

Задержка

на выходе

Клеммник 

прибора

Блокировка 

клавиш

Предустановки

PRESET LEVELS

MODELS

Модели

MODELS

Модели

MODELS

E48-111K

E48-112K

E48-211K

E48-311K

E48-111K

E48-111K

E48-112K

E48-112K

E48-211K

E48-211K

E48-311K

E48-311K

1 предустановка

1 level

1 предустановка

1 level

2 предустановки

2 level

1 предустановка 

+ 1 предупреждение

1 level + prewarn

30 Гц

7 мc макс.

 

/

 

1 кГц, 5 кГцб 10 кГц

2 мс макс.

безконтактный вывод

 

n-p-n открытый коллектор

 

Постоянный ток 45В

 / 

10 мА макс

Non-contact output  

NPN Open-collector 

DC45V / 100mA MAX.

■ 

Подключение и клеммник

 | 

WIRING AND REAR TERMINALS

■ 

Спецификация

 | 

SPECIFICATIONS

■ 

Модели

 | 

MODELS

DIGIT

POWER SOURCE

BODY LENGTH

Предустановки

Источник питания

Вход

Длина корпуса

1 предустановка

2 предустановки

1 предустановка 

+ 1 предупреждение

1level  prewarn

2 level preset

1 level preset

Контакт/открытый 

коллектор/напряжение

(

На выбор

)

Contact/Open-collector

Voltage input

(SELECTABLE)

4 12

4 12

4 6

4 6

K/P

K/P

K/P

K/P

Выводы клеммника для блокировки клавиш 

Short terminals to activate key protect.

Минипереключатель 8 отключен 

Dip SW8 is deactivated.

ВНИМАНИЕ

Note :

REAR TERMINALS

KEY PROTECT

Спецификация и печатные материалы могут быть изменены 

без предварительного предупреждения.

Последнее пересмотрение от Февраль 27, 2012.

Все права защищены

©

2012, LINE SEIKI C

O

., L

TD

.

AC100

240V

AC100

240V

DC12

24V

30Hz

7ms MAX.

 

/

 

1kHz,5kHz,10kHz

2ms MAX.

Summary of Contents for E48 Series

Page 1: ...sunlight dust high temperature and high humidity Do not attempt to disassemble or modify this device Mount to the front panel when using this device Indoor use Do not use organic solvents such as thin...

Page 2: ...tput 2 goes away OUT1 of 2 Level Preset PW or Prewarn 1 Level Preset All Models for all standard out put Hold Output is Latched until a Reset signal is sent Output is Latched until a Reset signal is s...

Page 3: ...be selected from the following settings 0 0 0 0 00 0 000 Default setting is 0 Write Any desired value can be set on the unit as the starting count value of the counter The counter will add to or subt...

Page 4: ...t of 2 level preset model main output of 1P 1PW model 1 level preset 2 level preset 1 level preset prewarn Key 1 will select the desired value Keys 2 4 will change digits Key 1 will select the desired...

Page 5: ...6 2 3 4 5 COM GND RES OUT N O N C IN A IN B 5 4 3 8 9 10 12 2 6 11 1 7 9 10 100 240VAC 9 10 12 24VDC 2 90 2 DC 9 3 IN A IN B GND 4 2 1 IN A IN B 12V GND 4 3 2 1 IN A IN B GND 4 2 1 IN A IN B GND 4 2...

Page 6: ...ot OUT1 one shot or HOLD1 OUT2 HOLD Reset Output 1 Output 2 SET2 SET1 W In case of 1 level preset models operation is the same as OUT 2 operation OUT1 one shot or HOLD1 OUT2 one shot OUT1 HOLD2 OUT2 o...

Page 7: ...ET1 W OUT1 one shot or HOLD1 OUT2 one shot OUT1 HOLD2 OUT2 one shot Standard Output Reset Output 1 Output 2 SET2 SET1 W OUT1 one shot or HOLD1 OUT2 one shot OUT1 HOLD2 OUT2 one shot In case of 1 level...

Page 8: ...mes Relay output 30Hz 17ms MAX 1kHz 5kHz 10kHz 12ms MAX 30 17 1 5 10 12 Blue STN LCD display with white backlight Digit Size 10mm 5mm MODEL DISPLAY NO OF DIGITS NO OF DIGIT SETTING KEYS PRESET LEVEL S...

Page 9: ...PW E C OUT C E OUTPUT DELAY PRESET LEVELS MODELS MODELS MODELS E48 111 E48 112 E48 211 E48 311 E48 111 E48 111 E48 112 E48 112 E48 211 E48 211 E48 311 E48 311 1 1 level 1 1 level 2 2 level 1 1 1 leve...

Page 10: ...C N O COM N O COM N O COM Short terminals to activate key protect 8 Dip SW8 is deactivated Note PRESET LEVELS MODELS E48 101K E48 102K E48 201K E48 301K 1 1 level 1 1 level 2 2 level 1 1 1 level prew...

Page 11: ...W E C OUT C E OUTPUT OUTPUT DELAY PRESET LEVELS MODELS MODELS MODELS E48 111K E48 112K E48 211K E48 311K E48 111K E48 111K E48 112K E48 112K E48 211K E48 211K E48 311K E48 311K 1 1 level 1 1 level 2 2...

Reviews: