background image

User Manual 

 

English 

 

 

 

 

 

 

E.g.: @W 00 00 #: Output 1 display Input1 
 
Output 1             Input1 

EDID Setting 

@W XX AA BB # 

Parameter Description:  

 
XX

 for configuration of 

“INPUT EDID”

 

  

Command 

05 

06 

07 

08 

15 

16 

17 

18 

Description 

Input1  Input2  Input3  Input4  Input5  Input6  Input7  Input8 

  

 

AA

 for selecting 

“Video Mode”

  

Command 

00 

01 

02 

03 

Description 

1080P 

4K2K_30 

4K2K_60(YC420)  4K2K_60(YC444) 

 

 
BB

 for selecting below function 

Bit7 

Bit6 

Bit5 

Bit4 

Bit3 

Bit2 

Bit1 

Bit0 

HDR 

48Bit 

36Bit 

30Bit 

7.1CH 

5.1CH 

2CH 

3D 

 

“1” : choose the function, “0” : doesn’t choose the function 
 
E.g. 11001001: HDR, 48Bit, 7.1CH, 3D 
Change Binary code “11001001” to hexadecimal format “C9” 

 
E.g. @W 05 03 C9 # 
The EDID of input 1 is: 4K2K_60(YC444), HDR, 48Bit, 7.1CH, 3D 

 

Web Control 

The default IP address of the Matrix is 192.168.0.103. Your PC must be in the same IP range to allow 
you access to it. For TCP/IP4 you can use and IP address in the range 192.168.0.2 to 192.168.0.254 
excluding 192.168.0.103. 

Open a web browser and enter the IP address 192.168.0.103 

Port Page 

– Set your Input and Output ports 

 

 

00 

Input1 

01 

Input2 

02 

Input3 

03 

Input4 

04 

Input5 

05 

Input6 

06 

Input7 

07 

Input8 

Summary of Contents for 38248

Page 1: ...p FIRST EDITION 8x8 HDMI 2 0 18G Matrix Pro User Manual English Benutzerhandbuch Deutsch Manuel Utilisateur Français Manuale Italiano No 38248 lindy com Tested to Comply with FCC Standards For Home and Office Use ...

Page 2: ......

Page 3: ...s RS232 IR remote control IP control for switching Specification Input Ports 8 x HDMI Female RJ45 Female RS232 Female 3 5mm IR Female USB Micro B Female Output Ports 8 x HDMI Female 8 x SPDIF Female Power Supply DC 12V Dimensions 440x220x44 5mm 17 32x8 66x1 75in Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 10 C 60 C 50 F 140 F Relative Humidity 20 90 RH Non condensing Power Consum...

Page 4: ...t 8 for 3 seconds to lock unlock all button functions on the front panel IP Address DHCP Press and hold input 7 for 3 seconds to check the IP address and DHCP A single press of input 7 will toggle the IP and DHCP information Press and hold input 5 to exit this mode unction Pressing output 3 and output 4 for 4 seconds will restore the factory settings Rear Panel 1 RJ45 port for IP control 2 RS232 c...

Page 5: ...or all inputs to outputs E g input 1 to output 1 input 2 to output 2 RS232 Pin Assignment Matrix Remote Control Console Assignment PIN Assignment 1 NC Tx 2 Rx Rx 3 Tx 4 NC GND 5 GND 6 NC 7 NC 8 NC 9 NC Software Control Download the latest version of the control software from the Lindy website Using either a RS232 cable or a USB cable connect the matrix to a PC or laptop COM Setting select and conn...

Page 6: ...rrent connection status click clear to clear the display information EDID Config Read and configure the EDID for each input such as HDR 3D data rates and audio channel IP Config You can manually set the IP address and the MAC address or you can set the router to assign the IP automatically by clicking DHCP ...

Page 7: ...o configure the PC and the Matrix to be in the same LAN Click Net config Connect Search Device Sel Device Number Connect when you can see the device name it means connection was successful System Config Power On Off reset or set default settings ...

Page 8: ...mand in the send options Command Function Note W 04 00 01 02 03 PTP Function Mirror all inputs and outputs Ex Input 1 to output 1 input 2 to output 2 etc W 50 Reboot W 51 Restore Factory Setting W 0F 00 Standby 00 Standby Mode 01 Cancel Standby Mode Command Description 00 Output1 01 Output2 02 Output3 03 Output4 11 Output5 12 Output6 13 Output7 14 Output8 04 All Output ...

Page 9: ... 2CH 3D 1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0 1 choose the function 0 doesn t choose the function E g 11001001 HDR 48Bit 7 1CH 3D Change Binary code 11001001 to hexadecimal format C9 E g W 05 03 C9 The EDID of input 1 is 4K2K_60 YC444 HDR 48Bit 7 1CH 3D Web Control The default IP address of the Matrix is 192 168 0 103 Your PC must be in the same IP range to allow you access to it For TCP IP4 you can use...

Page 10: ...User Manual English EDID Set Page Edit the EDID settings for each input port IP Config Page Rename the device and enable disable DHCP ...

Page 11: ...tallation You are cautioned that changes or modification not expressly approved by the party responsible for compliance could void your authority to operate the equipment This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interferen...

Page 12: ... Gerätehersteller LINDY bietet deutschen Endverbrauchern ein kostenloses Rücknahmesystem an beachten Sie bitte dass Batterien und Akkus den Produkten vor der Rückgabe an das Rücknahmesystem entnommen werden müssen und über die Sammel und Rückgabesysteme für Batterien separat entsorgt werden müssen Ausführliche Informationen zu diesen Themen finden Sie stets aktuell auf der LINDY Webseite im Fußber...