Reboot command package length is 18byte: 
50 56 54 08 0D 00 00 00 00 00 00 00 00 00 00 00 00 0F 
Standby Mode command package length is 18byte: 
Power on: 50 56 54 08 0B 0F 00 0F 00 00 00 00 00 00 00 00 00 2B  
 
Power off: 50 56 54 08 0B F0 00 F0 00 00 00 00 00 00 00 00 00 ED 
 
Standby Mode query command package is 18byte: 
This is a query command which mean you must send query package and then receive an answer. 
For example: 
Send package: 50 56 54 08 0C 00 00 00 00 00 00 00 00 00 00 00 00 0E  
Receive package: 50 56 54 08 0C 0F 00 00 00 00 00 00 00 00 00 00 00 1D 
The blue 0F mean Power on, if F0 mean Power off. 

IR Command List 

NEC code 
#define SYSTEM_CODE  

0x00 

 
#define IR_KEY_POWER               0x14 
 
#define IR_KEY_OUTPUT_1_FROM_1     0x09 
#define IR_KEY_OUTPUT_1_FROM_2     0x1D 
#define IR_KEY_OUTPUT_1_FROM_3     0x1F 
#define IR_KEY_OUTPUT_1_FROM_4     0x0D 
#define IR_KEY_OUTPUT_1_PRE        0x1B 
#define IR_KEY_OUTPUT_1_NEXT       0x11 
 
#define IR_KEY_OUTPUT_2_FROM_1     0x17 
#define IR_KEY_OUTPUT_2_FROM_2     0x12 
#define IR_KEY_OUTPUT_2_FROM_3     0x59 
#define IR_KEY_OUTPUT_2_FROM_4     0x08 
#define IR_KEY_OUTPUT_2_PRE        0x55 
#define IR_KEY_OUTPUT_2_NEXT       0x48 
 
#define IR_KEY_OUTPUT_3_FROM_1     0x5e 
#define IR_KEY_OUTPUT_3_FROM_2     0x06 
#define IR_KEY_OUTPUT_3_FROM_3     0x05 
#define IR_KEY_OUTPUT_3_FROM_4     0x03 
#define IR_KEY_OUTPUT_3_PRE        0x07 
#define IR_KEY_OUTPUT_3_NEXT       0x40 
 
#define IR_KEY_OUTPUT_4_FROM_1     0x18 
#define IR_KEY_OUTPUT_4_FROM_2     0x44 
#define IR_KEY_OUTPUT_4_FROM_3     0x0f 
#define IR_KEY_OUTPUT_4_FROM_4     0x51 
#define IR_KEY_OUTPUT_4_PRE        0x1E 
#define IR_KEY_OUTPUT_4_NEXT       0x0E 