background image

English 

Manual 

        

 

 

11

 

© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH  -  FIRST EDITION (DEC 2001) 

 

F5 ADM: 

Only available for the administrator! 

F5 opens a sub menu showing options for the configuration of the CPU Switch MultiMedia. Please note 
that changes will affect all users that are logged in as administrator at the same time. 

The following sub menus will be listed:  
 

Setting Function 
SET PASSWORD 

This function is used to set passwords for the Administrator and User: 
One Administrator and four User passwords can be set. Move the 
highlight bar to User or Administrator, then press [Enter]. A screen that 
allows you to key in your password appears. The password maybe up to 
8 characters long and can consist of any combination of letters and 
numbers (A - Z, 0 - 9). You are asked to key the password in twice to 
make sure there is no typing mistake. 
To modify or delete a previous password, use the backspace key. If the 
Administrator wants to change a user’s password, he must enter their 
administrator’s password first. 

SET ACCESSIBLE 
PORTS 

This function allows Administrators and Users to select, which Ports can 
be accessed, from a particular Console.  
If access is ON, a plus mark ( + ) has to be selected, space (  ) means 
that access is not possible. Selection is made by ENTER or SPACEBAR. 

SET ACCESS 
TIMEOUT 

A Multi-User Switch provides access to the selected ports to other users 
after the selectable delay TIMEOUT. TIMEOUT is adjustable from 2-255 
seconds. The time count starts after the last keyboard or mouse 
operation. Selecting “0” means that the port will be permanently blocked 
for all other users.  

CLEAR THE NAME 
LIST 

This function is used to undo all Administrator changes and return to 
the original factory default settings. 
Note: While this function is in progress, make sure that no other 
operations are performed on any of the other Consoles. 

RESTORE 
DEFAULT VALUES 

This function is used to undo all Administrator changes and return to 
the original factory default settings - except for the Names that were 
assigned to Ports 

RELEASE ALL 
PRIVAT 

Releases all Ports that have been set to Private Mode (see Private 
Mod
e), so that they become accessible to all Consoles. 

SET LOGOUT 
TIMEOUT 

If a Console that has accessed by a computer is not used for the amount 
of time set with this function, the Operator is automatically logged out. A 
log in is necessary before the Console can be used again. This enables 
the other Consoles to gain access to the computers when the original 
Console is no longer accessing them, but the Operator has forgotten to 
relinquish access. To set the timeout value, key in a number from 1-255 
minutes. If the number is 0 [zero], this function is disabled. Default is 5 
(five) minutes. 

SET MULTIUSER 
MODE 

This function determines whether the same ID can be used to log into 
the CPU Switch MultiMedia from different Consoles at the same time. 

1. If Disabled, the same ID cannot be used; if Enabled (the default), 
the same ID can be used to log in from more than one Console. 
2. If Enabled, the F4, F6, and F7 settings set for any one Console, 
will be the same for all other Consoles that log in with the same ID. 
3. Changes made to the F4, F6, and F7 settings by any logged in 
Console will automatically affect all Consoles with the same ID. 

 

Summary of Contents for 2X8

Page 1: ...LINDY ELECTRONICS LIMITED LINDY ELEKTRONIK GMBH FIRST EDITION DEC 2001 CPU Switch MultiMedia 2X8 Manual English Benutzerhandbuch Deutsch 2 User 8 PC LINDY Art Nr 32812 4 User 8 PC LINDY Art Nr 32814...

Page 2: ...ad this manual thoroughly and follow the installation and operation procedures carefully to prevent any damage to the LINDY CPU Switch unit and or any of the devices connected to it We have tried to k...

Page 3: ...ate all machines from your regular desk The switching between the connected PCs servers is easily done by selecting the PCs from the On Screen Display OSD of the CPU Switch All PCs are displayed arran...

Page 4: ...used with this CPU Switch The first two consoles are connected via standard connection cables for SVGA PS 2 and Audio Stereo with 3 5mm Stereo connectors but also LINDY KVM cables including SVGA and...

Page 5: ...nd need to be reset carefully insert a pointed object in here and push 5 Power LED Lights blue to indicate that the LINDY CPU Switch MultiMedia is turned on and receiving power 1 Power switch ON OFF 2...

Page 6: ...appropriate LINDY systems cables as described before in chapter CABLES 3 Connect the enclosed power supply to the mains and plug in its DC power cable to the CPU Switch 4 Switch on the CPU Switch The...

Page 7: ...ends the access 2 Solution for fully simultaneous access for a certain amount of servers Users are connected to the CPU Switch LITE series switches LITE OSD 8 or LITE 2 or LITE 4 Multiple CPU Switch M...

Page 8: ...te installation please follow the following steps First power down all PCs or downstream cascaded CPU switches and PCs connected to the CPU switch you want to power down Then power down the CPU Switch...

Page 9: ...nnected and powered up with a symbol like a sun NAME If a name was given it will be showed here For security purpose the OSD also includes a multi level password protection for up to 4 users and one a...

Page 10: ...first user is disconnected see F5 ADM Set Access Timeout Also if cascaded no input to this port is possible AND the screen stays dark OSD Display window of selected port server The OSD can show the s...

Page 11: ...g and changing of the information displayed in the OSD and the auto scan settings Choice Meaning ALL Lists all Ports and servers with their name QVIEW Lists only the ports having been selected for aut...

Page 12: ...means that the port will be permanently blocked for all other users CLEAR THE NAME LIST This function is used to undo all Administrator changes and return to the original factory default settings Not...

Page 13: ...at have been named SCAN DURATION Selects the dwell time per port in auto scan selectable 1 255 seconds PRIVATE MODE ENABLE This port computer can be accessed from this console only after being selecte...

Page 14: ...ue 2 If you re enter the OSD after logging out and immediately use Esc to deactivate the OSD without having selected a port from the OSD menu a Null Port message displays on the screen and the system...

Page 15: ...socket VGA SVGA Console ports 1 2 Audio 2 consoles with 2 x 3 5mm stereo socket Console ports 3 4 Version 4x8 only 2 consoles with system cable for monitor mouse keyboard speaker and microphone PC por...

Page 16: ...hat the EMC compatibility is not badly influenced FCC Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harm...

Page 17: ...e die hilfreichen Installations und Bedienhinweise um Besch digungen des CPU Switch oder der angeschlossenen Rechner zu vermeiden Wir haben uns M he gegeben es so kurz und knapp wie m glich aber trotz...

Page 18: ...er sind vom gewohnten Arbeitsplatz mit allen lokalen Unterlagen aus bedienbar Das Umschalten zwischen den angeschlossenen Rechnern erfolgt bequem ber die OSD Auswahl Im OSD werden alle angeschlossenen...

Page 19: ...zielle Systemkabel verwendet siehe unten stehende Tabelle Prinzipiell werden die ersten beiden Arbeitspl tze mit SVGA Kabel Monitor und PS 2 Kabel Tastatur und Maus sowie Audio Stereo Kabel angeschlos...

Page 20: ...oder einen Kugelschreiber um diesen versenkten Taster zu bet tigen dies l st einen Warmstart des CPU Switch aus Wird die Taste l nger als 3 Sekunden gehalten so l st dies einen Kaltstart aus 5 Power...

Page 21: ...eine Steckdose und verbinden Sie anschlie end das Niederspannungskabel mit der Buchse f r die Stromversorgung am CPU Switch 4 Schalten Sie den CPU Switch ein Der Switch f hrt nun einen Power On Selbs...

Page 22: ...n einer komplexen Matrix mit Voll Simultanzugriff f r 4 User gesteuert werden Hierf r werden ben tigt 4 LINDY CPU Switch MultiMedia 4x8 sowie 4 weitere Einzel User CPU Switch mit mindestens 4 Ausgangs...

Page 23: ...lte einen Ihrer LINDY CPU Switches auszuschalten m ssen Sie wie folgt vorgehen Fahren Sie alle Rechner die mit dem Ger t verbunden sind sowie alle auf niedrigeren Ebenen kaskadierten CPU Switches und...

Page 24: ...ie angeschlossen eingeschaltet und On line sind mit einem sonnigen Symbol NAME Wenn f r einen Anschluss ein Name vergeben wurde wird dieser hier angezeigt F r Sicherheitsbelange wird ber das OSD ferne...

Page 25: ...gaben auf diesem Rechner m glich Dies gilt analog auch f r kaskadierte Ports allerdings bleibt der bildschirm dunkel Anzeige des ausgew hlten Rechners Das OSD des CPU Switch erlaubt die Anzeige des au...

Page 26: ...ung ALL Listet alle CPU Switch Ports mit Namen QVIEW Listet nur die Anschl sse die f r den Zugriff im Quick View Scan Modus selektiert wurden POWERED ON Listet nur die Anschl sse an denen die angeschl...

Page 27: ...nach der letzen Eingabe Maus oder Tastaur Der Wert 0 beduetet hier dass der Rechner nicht freigegeben wird bis der Benutzer auf einen anderen Rechner umschaltet CLEAR THE NAME LIST Setzt ALLE Einstel...

Page 28: ...kierung des OSD Eintrag QV POWERED ON alle eingeschalteten POWERED ON QVIEW alle eingeschalteten mit Eintag QV QVIEW NAME alle mit Eintrag QV und mit Namen NAME nur die die einen Namen haben SCAN DURA...

Page 29: ...Keine Funktion von Tastatur und oder Maus Versuchen Sie zuerst durch Umschalten und Zur ckschalten wieder Zugriff auf den Rechner zu erlangen Pr fen Sie ob die zum Port Rechner zugeh rige ONLINE LED a...

Page 30: ...Konsolen mit HD 15 Buchse VGA SVGA Konsolen anschl sse 1 2 Audio 2 Konsolen mit 2x 3 5mm Stereo Buchse Konsolen anschl sse 3 4 Nur bei Version 4x8 2 Konsolen mit Systemkabel f r Monitor Maus Tastatur...

Page 31: ...eferten Netzteil betrieben werden Nur in diesem Fall kann von der Einhaltung der EMV Kompatibilit t ausgegangen werden vorausgesetzt alle im System integrierten Komponenten erf llen ebenfalls ihrersei...

Page 32: ...ELEKTRONIK GMBH FIRST EDITION DEC 2001 English Manual Deutsches Benutzerhandbuch LINDY CPU Switch MultiMedia Models 2X8 and 4X8 Full Audio Support Simultaneous Multi User 2 User 8 PC LINDY Art Nr 3281...

Reviews: