LHA35RM 1 GHz MDU Distribution Amplifier

Installation Manual

Page 2 of 3

SPECIFICATIONS

Parameter

Specification 

(1)

Forward GaAs FET Push-Pull

Reverse

Bandwidth

54-1000 MHz

5-42 MHz

Full Gain (Min.) 

(2)

35 dB

18 dB

Flatness

± 1 dB

Return Loss

In/Out

-16 dB

Test Points 

-30 dB (output)

Gain Control

Variable

0-20 dB (input)

0-20 dB (output)

Slope Control

Variable

0-20 dB cable (input)

Fixed Equalizers 

(3)

Mid-stage

Forward Distortions: 42 dBmV flat output (79 channels) 

(4)

CTB

On CH 78

-62 dBc

CSO

On CH 78

-66 dBc

XMOD

On CH 2

-60 dBc

Forward Distortions: ref 44 dBmV output (79 channels, 12 dB intersage slope, 54-1000 MHz) 

(4)

CTB

On CH 78

-65 dBc

CSO

On CH 78

-72 dBc

XMOD

On CH 2

-63 dBc

Reverse Distortions: 52 dBmv flat output, 4 CH
3rd on T10

T8+T9-T7

-68 dBc

2nd on T9

T7+12 MHz

-65 dBc

XMOD on T10

T7, T8, T9, T10

-64 dBc

Noise Figure

7 dB

Group Delay

Fwd (55, 25-58.83 MHz)

38 ns (max.)

Rev (41-42 MHz)

35 ns (max.)

Power, Environmental & Physical

Hum Modulation

-70 dB

RFI Isolation

5-1000 MHz

-100 dB

Surge Withstand

In/Out

IEEE C62.41-Cat A3, 6 kV, 200 A

Powering 

Mains, 117 VAC

Power Consumption

8 W

Enclosure

IP54 category, diecast aluminum

Operating Temperature

-10°C to +55°C (+14°F to +131°F)

Dimensions (H x W x D)

7.6”H x 5.4”W x 3.0”D (19.3H x 13.7W x 7.6D cm)

Weight

3.8 lb (1.7 kg)

NOTES:
(1)

 Specifications are typical, for T=20°C, ZIN=ZOUT=75 ohms

(2)

 Tolerance on station gain is ± 2.0 dB

(3)

 Model GE XX equalizers available in 12 & 14 dB at 1000 MHz

(4)

 Digital output levels are lower

NOTE TO CATV SYSTEM INSTALLER

This reminder is provided to call the CATV system installer’s attention to Article 820-40 of the NEC that provides guidelines for proper grounding and, in particular, 

specifies that the cable ground shall be connected to the grounding system of the building, as close to the point of cable entry as practical.

INSTALLATION & SETUP GUIDELINES

1. 

Adjustable gain and cable slope controls are reachable under the cover. Refer to layout scheme for adjustable controls.

2. 

This product is shipped with default 0 dB pad for plug-in interstage equalization.

3. 

Before applying power to the amplifier make sure that the forward input level to the amplifier is not too high or damage to the amplifier might occur. To be on the safe 

side, you should set the input gain control adjustment to minimum gain (fully counter clockwise) before powering the LHA.

4. 

Set the input equalizer control for minimum slope (fully clockwise) and install a 0 dB plug in equalizer (factory installed) into the mid-stage equalizer socket.

5. 

Now apply power to the amplifier and measure the amplifier forward output level at the 30 dB output test point. If it is very low then turn the input gain control 

clockwise to increase the gain until the desired output level is reached at the highest operating frequency. Remember that the level measured at the test point is 30 

dB lower than the real signal level.

6. 

Turn the input equalizer control to adjust the forward output level to be flat across the full bandwidth. The input signal level will now be flat too. Under this condition 

there will be best CNR across the full bandwidth.