LBDG-100-DC
SECTION 3 INSTALLATION
Installation of the LBDG-100-DC DOCSIS 3.0 Gateway is similar to the
installation of a line extender or any other piece of CATV equipment.
The DOCSIS Gateway can be connected to a power-passing coupler or
splitter. Call Lindsay Broadband for the recommended power insertion
device for your application.
3.1 Pre-Installation
Upon receipt of the LBDG-100-DC, inspect the carton for any external
damage. If damage is present, inspect the Gateway exterior for
damage. Report any apparent damage to the shipping agent and the
Lindsay Broadband sales office.
Pad values can be determined ahead of time. The loss of the HFC
interface board should be accounted for when calculating pad values.
There is -4dB of loss in the reverse direction and -5dB of loss in the
forward direction. The forward pad should be selected such that the
power incident on the cable modem is 0dBmV ( +5dBmV at the Gateway
KS connection). For best return path S/N, the reverse pad should be
selected so as to have the cable modem operate near its maximum
output level (+50 to +52dBmV).
The cable modem can be provisioned ahead of time using the MAC
address located on the label on the exterior of the Gateway lid.
A ½” wrench is needed for both the strand clamp and housing bolts.