Lindsay Broadband LBDG-100-DC Installation Manual Download Page 1

 

LBDG-100-DC 

 

 
 
 

LBDG-100-DC 

 

Strand Mount  

DOCSIS 3.0 Gateway 

with DC Power Output 

 
 

Installation Guide 

 
 

 

Summary of Contents for LBDG-100-DC

Page 1: ...LBDG 100 DC LBDG 100 DC Strand Mount DOCSIS 3 0 Gateway with DC Power Output Installation Guide...

Page 2: ...ents not recommended for this product as they may cause hazards SERVICING Remove power from this device and refer servicing to qualified personnel under the following conditions 1 If the inside of the...

Page 3: ...used replacement parts specified by the manufacturer or parts that have the same characteristics as the original part Unauthorized substitutions may result in fire electric shock or other hazards SERV...

Page 4: ...component identification diagrams installation instructions and specifications 1 2 General Description The DOCSIS 3 0 Gateway uses the HFC network to power and backhaul IP based devices It can be con...

Page 5: ...mately 406 x 228 x 165mm 16 x 9 x 6 5 not including connectors Its weight is around 6 9 Kg 15 3 Lbs 1 4 Major Components Internally the housing bottom contains the HFC interface board and DOCSIS 3 0 c...

Page 6: ...type surge protection A power interrupt to disconnect AC power SECTION 2 COMPONENTS IDENTIFICACION HFC INPUT SURGE ARRESTOR AC INTERRUPT DC POWER TO DEVICE EMI SEAL WEATHER SEAL CABLE MODEM UPSTREAM D...

Page 7: ...ipping agent and the Lindsay Broadband sales office Pad values can be determined ahead of time The loss of the HFC interface board should be accounted for when calculating pad values There is 4dB of l...

Page 8: ...quirements The DOCSIS 3 0 Gateway with DC Power Output can be connected to any power passing splitter or coupler The following formula can be used to calculate the current draw for your installation W...

Page 9: ...LBDG 100 DC 3 4 Output Receptacle Wiring...

Page 10: ...sured at the single test point Readings are 20dB below the levels seen at the cable modem Adjust pad values as required 8 Optional Silicone Grease can be applied to the exposed part of the O ring befo...

Page 11: ...nector body from the parts kit into the fixed body already installed in the Gateway Keep tightening until the flat washer just starts to compress and bulge outward This can be done by hand or with a w...

Page 12: ...LBDG 100 DC SECTION 4 LBDG 100 DC HOUSING DIMENSIONS 4 1 Housing Dimensions TOP VIEW RIGHT END SIDE VIEW SIDE VIEW FROM HINGE 16 375 9 750 1 875 6 375 1 250...

Page 13: ...ended HFC Return Loss 16dB Max Insertion Loss 5dB 1dB Test Point 20dB Relative to Cable Modem RF Port Pad Type JPX Separate Forward and Reverse Temperature Range 40 to 60 C 40 F to 140 F EMI Isolation...

Page 14: ...LBDG 100 DC...

Reviews: