4.0  INSTALLATION 

Application modules of LB-1000 can be installed in any of the general slots of the rack. Module is 
inserted into the rack from the front part.  
 

1) 

Gently insert the LB-1000 application module into any general slot (labelled 01 to 18) 
from the front of the chassis. Be careful to align the metal guide rails on the top and 
bottom of the module to the chassis housing. 

 

2) 

Using  the  handle  completely  push  the  application  module  into  the  slot.  Once  the 
module is completely inserted into the slot, the latch on the bottom of the module will 
lock into place with the LB-1000 chassis securing the module in the rack. Ensure that 
the application module is securely connected to the LB-1000-CH rear panel and F-
connectors. The application module will be automatically power “ON”. The Status LED 
on the front of the module will turn ON and the module will show up on the control 
module screen or web interface. 
 

 

Figure 3: LB-1000 application module installation

 

3) 

If the module hasn’t been properly connected to the LB-1000-CH it will not power up 
and status LED will be OFF. In such a case, remove the application module from LB-
1000-CH slot and reinsert carefully as described in steps 1 and 2 above. See below 
step for safely removing the module. 
 

4) 

To remove the application module from the slot, press down on the latch located in the 
bottom front of the module. The application module will unlock from the LB-1000-CH 
rack and the module can be removed. 

 

 

Summary of Contents for LB-1000-RR

Page 1: ...Aug 01 2019 LB 1000 RR Headend Platform Quad Return Receiver User Manual...

Page 2: ...ONTENTS ii 1 0 PRODUCT OVERVIEW AND FEATURES 1 1 1 Description 1 1 2 Features 1 1 3 Specifications 2 1 4 Block diagram of the LB 1000 RR 3 2 0 SAFETY NOTES 4 3 0 APPLICATION MODULE DESCRIPTION 5 4 0 I...

Page 3: ...e of optical input signals Module parameters can be monitored and configured through the LB 1000 CM system management module using the touch screen or by using the PC Web GUI or SNMP agent 1 2 Feature...

Page 4: ...o AGC in RFoG version Optical Return Loss 45 dB Number of Receivers 4 Connector SC APC RF Performance Bandwidth 5 205 MHz Return Loss 16 dB Flatness 0 75 dB Output Level 30 dBmV 18 dBm Rx in 35 OMI RF...

Page 5: ...terborough ON CANADA K9J 6X6 Ph 705 742 1350 or 800 465 7046 Email support lindsaybb com 3 P a g e LB 1000 RR User Manual 1 4 Block diagram of the LB 1000 RR Figure 1 Block diagram of the LB 1000 RR Q...

Page 6: ...s which connects to this LB 1000 RR exposure can cause permanent injury to eyes Avoid direct exposure to the laser light source Never stare directly into a fiber or at any mirror like surface that cou...

Page 7: ...LED will be green when the Return receiver module is operating normally and will be red when there is an alarm 2 The Test Point is a 20dB TP relative to the output port 3 Module Handle to draw the ap...

Page 8: ...nto place with the LB 1000 chassis securing the module in the rack Ensure that the application module is securely connected to the LB 1000 CH rear panel and F connectors The application module will be...

Page 9: ...bles are clean 7 Ensure optical jumper connectors are matched properly to the device adapters i e SC APC to SC APC Using mismatched connectors will damage the connectors and degrade system performance...

Page 10: ...n tap touch the corresponding application module slot 01 18 where the LB 1000 RR is plugged in The selected application module will be highlighted and the screen will show settings for the LB 1000 RR...

Page 11: ...n receiver Select main channel for back up operating mode Low Cut Mode ON OFF Enable or Disable optical protection mode Optical RF channel turned OFF when optical power below a certain level Only for...

Page 12: ...ication module slot 1 18 where the LB 1000 RR is plugged in The selected application module will be highlighted and the screen will show settings for the LB 1000 RR return receiver User can monitor pa...

Page 13: ...2 2035 Fisher Dr Peterborough ON CANADA K9J 6X6 Ph 705 742 1350 or 800 465 7046 Email support lindsaybb com 11 P a g e LB 1000 RR User Manual Figure 7 LB 1000 RR Web Interface...

Page 14: ...2 2035 Fisher Dr Peterborough ON CANADA K9J 6X6 Ph 705 742 1350 or 800 465 7046 Email support lindsaybb com 12 P a g e LB 1000 RR User Manual 6 0 WARRANTY AND RMA POLICY...

Page 15: ...URNS 1 Fill out the Product Return Authorization Form indicating product information Repair items do not require original invoice information but it is helpful to determine warranty eligibility 2 Cont...

Page 16: ...d 2 Products are accompanied by a one dollar new purchase for one dollar credit return order 3 Products were purchased within one year from credit return date and are in a current catalog 4 Products a...