Introduction:
Thank you for deciding to purchase a LINDR product.
This manual is intended for models: :
SODA PYGMY, SODA ELEGANCE, SODA ELEGANCE
TOWER, SODA AS - 45
General instructions and precautions:
When using the machine be sure to follow the basic
safety precautions. These machines are design to
produce carbonated water from H2O and CO2, and also
to cool water, optionally beverage (SODA AS-45). The
temperature of the water and soda water is adjustable
by the thermostat in the range between 4 °C - 10 °C.
DO NOT USE FOR ANY OTHER PURPOSES THAN
INTENDED BY THE MANUFACTURER!
General safety rules.
The supplier shall not be liable for any damage caused
by activities carried out on this equipment without
following these instructions.
CAUTION:
Before connecting the main power supply, check that
the voltage and frequency corresponds to the
specifications of the machine.
Make sure that the socket outlet to which you are
connecting the cooling machine is provided with a
sufficient breaker (16A according to type) according to
ČSN 33 1500.
Before any cleaning or maintenance, always unplug the
machine from the power supply: Put the main switch
(thermostat) to position "O" and pull out the plug.
Never put tools or other objects into the fan blades.
Never touch electrical parts with wet or damp hands.
To ensure the performance of the cooling machine,
never block the air inlet.
CAUTION:
CAUTION:
CAUTION:
CAUTION:
CAUTION:
DO NOT USE FOR ANY OTHER PURPOSES THAN
INTENDED BY THE MANUFACTURER!
Stand the cooling machine on a solid surface in a
horizontal position before the first connection and
leave it for about 2 hours to stabilize with the ambient
conditions.
CAUTION:
COOLER MUST NOT lay on its side EVEN FOR
TRANSPORTATION.
Use the machine preferably in a well ventilated room.
The machine
MUST NOT BE
used or stored at
temperatures below 0 ° C.
The machine is intended for use in a normal
environment according to ČSN 33 2000-3 norm and is
classified
in a climatic class N.
THE MACHINE SHOULD NOT BE NEAR ANY HEAT
SOURCES OR EXPOSED TO DIRECT SUNLIGHT.
For proper operation, it is important not to obstruct any
ventilation openings.
Warning:
The electrical equipment must be revised and the dates
checked according to CSN 33 1600 norm by
knowledgeable and authorized person.
Service and
spare parts, required inspections are carried out by
LINDR.
RECOMMENDED SETTINGS
1.Setting of water supply:
Water pressure should be constant and must not
exceed 3.0bar
RECOMMENDATION:
Install a pressure reducer for water
2. Setting of Co2:
Set the Co2 pressure reducer to
4bar (max. up to 4.5bar). The amount of Co2 pressure
affects the saturation.
3.Temperature:
Adjust the temperature of cooled beverage by the
mechanical termostatatu in the range 4 ° C to 10 ° C. The
thermostat has a numeric scale from 1 to 7.
(Except the SODA ELEGANCE where the temperature is
set automatically)
Installation and location:
8.
No.1
= maximum
temperature of the
beverage 10 ° C
No.7
= minimum
temperature of the
beverage 4 ° C
0 = off
Summary of Contents for SODA AS - 45