A-3
INSTALLATION
TCV400
A-3
Failure to follow these instructions can cause immedi-
ate failure of components within the machine. When
powering machine from a generator be sure to turn off
the machine first, before generator is shut down in
order to prevent damage to machine.
OUTPUT CABLE CONNECTIONS
The output leads are connected to the output termi-
nals marked “
+
” and “
-
” (low inductance) or
“
-
”
(
high inductance). They are located at the
lower right and lower left corners of the front panel.
The TCV400 provides Tweco weld cable connector
receptacles.
OUTPUT CABLES
CABLE SIZES FOR COMBINED LENGTH OF ELEC-
TRODE AND WORK CABLE
400A
(100% DUTY
CYCLE)
500A
(50% DUTY
CYCLE)
MACHINE LOAD
CABLE LENGTHS
UP TO 50 ft
(15m)
50 to 100 ft
(15-30 m)
100-150 ft
(30-46 m)
150-200 ft
(46-61 m)
200-250 ft
(67-76 m)
3/0
85 mm
2
3/0
85 mm
2
3/0
85 mm
2
3/0
85 mm
2
4/0
107 mm
2
2/0
67 mm
2
2/0
67 mm
2
3/0
85 mm
2
3/0
85 mm
2
4/0
107 mm
2
FIELD INSTALLED OPTIONS
ELECTRIC SHOCK can kill.
•
Turn the power switch of the power
source “
OFF
” before installing plugs on
cables or when connecting or discon-
necting plugs to power source.
------------------------------------------------------------
WARNING
CAUTION
WHEEL KIT
For easy moving of the machine an optional platform
Wheel Kit
601547
is available.
Install per instructions provided with Wheel Kit.
METER KIT
Ammeter and Voltmeter Kit
610706
is available.