Owner Manual
Technical Description
Note: The pump operation can be checked from the outside by
observing whether the stirring paddle is rotating (e.g. by trigge-
ring an additional lubrication), whether the LED on the printed
circuit board are lit or whether the external relay has picked up.
Cause:
Voltage supply interrupted
Voltage supply to the printed-circuit interrupted
Printed circuit board defective
Remedy:
Check the voltage supply to the pump. If necessary, correct
the cause of the fault.
Check the line leading from the pump plug to the printed cir-
cuit board.
If the voltage is applied, the left-hand LED is lit.
Replace the printed circuit board.
Fault: The pump motor does not run
Cause:
Piston detector (initiator) defective.
Cable connection of the piston detector to the pump interrup-
ted
Printed circuit board defective
Remedy:
Disconnect the main line leading to the monitored metering
device.
Unscrew the piston detector and check it. For this, insert a
metallic pin into the borehole of the detector. Let it there over
2 seconds and then remove it. If the pump is not switched off
afterwards, check the cable conections to the pump. If neces-
sary, replace the piston detector with the connector.
Check the cable connections to the pump. If necessary, repla-
ce the piston detector with the connector.
Replace the printed circuit board
Fault: The pump motor supplies permanently (5 minutes or 30 minutes )- Duration of the monitoring time
The printed circuit boards model
M
comply with the EMC guide-
line 89 / 336 / EWG
Emitted interference acc. to .................... EN 55011 / 03.91 and
......................................................... EN 50081-1 / 01.92
Noise immunity acc. to .............................. prEN 50082-2 / 1993
Time Setting
Pause time, acc.to jumper position:
...................................................4, 8, 12,...to 60 minutes
......................................................... 1, 2, 3...to 15 hours
The operating time is switched off via the piston detector.
Factory setting
Pause time ........................................................... 6 hours
or .................................................................... 24 minutes
Monitoring time ................................................ 5 minutes
or .................................................................... 30 minutes
Rated voltage ............................................................ 12/24V DC
Operating voltage
12V/ 24V .......................................................... 9V to 30V
Residual rippple in relation
with the operating voltage .................... ± 5% acc. to DIN 41755
Motor output ............................. transistor 7A/short-circuit proof
Reverse voltage protection:
The operating voltage inputs are protected against
polarity reversal
Temperature range: .................................. -25°C to 70°C
Output fault/readiness for operation
transistor 3A/short-circuit proof
Protection
Printed circuit board installed in housing ..................... IP 6K 9K
In order to protect the printed circuit board against condensati-
on, it is covered with a protective varnish.
Technical Data
Troubleshooting