![Lincoln LN-25 IRONWORKER Operator'S Manual Download Page 19](http://html.mh-extra.com/html/lincoln/ln-25-ironworker/ln-25-ironworker_operators-manual_1917948019.webp)
Maximum WFS
Standard Spin
Gearing
280
340
440
520
600
Minimum Arc Volts
15 V
17 V
21 V
24 V
27 V
WIRE FEED SPEED KNOb
Wire Feed Speed, CV Operation
When Across the Arc models are operated with CV
power sources, the wire feed speed will remain a con-
stant value, independent of arc voltage changes, as
along as the arc voltage does not drop below the val-
ues per the following table.
83% Wire Feed Speed
The 83% wire feed speed reduces the wire feed
speed to 83% of the original set value when activated.
For example, if the original wfs = 200 in/min, the feed-
er will regulate to 0.83 x 200 = 166 in/min.
The 83% trigger requires a gun with a dual procedure
switch.
This feature is often useful when welding pipe, and a
“cooler” procedure is required on the bottom portion.
b-3
OPERATION
b-3
(See
Customer Assistance Policy
in the front of this
Instruction Manual)
CASE FRONT CONTROLS
(See Figure b.1)
ITEM DESCRIPTION
1
Wire Feed Speed/Amperage Display
2
Wire Feed Speed LED
3
Amperage LED
4
Wire Feed Speed Knob
5
5 pin gun trigger connector
6
Work Clip Connection
7
Thermal LED
8
Voltage Display
9
Voltage LED
10
Set-up Push Button
LN-25™ IRONWORKER
1
5
2
6
7
8
9
10
3
4
FIGURE b.1
CV OPERATION