background image

 

English  

English 

1

 

Safety 

01/11 

 

WARNING

 

This equipment must be used by qualified personnel.  Be sure that all installation, operation, maintenance and repair 
procedures are performed only by qualified person.  Read and understand this manual before operating this equipment.  
Failure to follow the instructions in this manual could cause serious personal injury, loss of life, or damage to this 
equipment.  Read and understand the following explanations of the warning symbols.  Lincoln Electric is not responsible 
for damages caused by improper installation, improper care or abnormal operation. 
 

 

WARNING:  This symbol indicates that instructions must be followed to avoid serious personal injury, 
loss of life, or damage to this equipment.  Protect yourself and others from possible serious injury or 
death. 

 

READ AND UNDERSTAND INSTRUCTIONS:  Read and understand this manual before operating 
this equipment.  Plasma cutting or gouging can be hazardous.  Failure to follow the instructions in this 
manual could cause serious personal injury, loss of life, or damage to this equipment. 

 

ELECTRICALLY POWERED EQUIPMENT:  Turn off input power using the disconnect switch at the 
fuse box before working on this equipment.  Ground this equipment in accordance with local electrical 
regulations. 

 

ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS:  Electric current flowing through any 
conductor creates electric and magnetic fields (EMF).  EMF fields may interfere with some 
pacemakers, and welders having a pacemaker shall consult their physician before operating this 
equipment. 

 

CE COMPLIANCE:  This equipment complies with the European Community Directives. 

 

ARTIFICIAL OPTICAL RADIATION:  According with the requirements in 2006/25/EC Directive and  
EN 12198 Standard, the equipment is a category 2.  It makes mandatory the adoption of Personal 
Protective Equipments (PPE) having filter with a protection degree up to a maximum of 15, as 
required by EN169 Standard. 

 

WORK MATERIALS CAN BURN:  Cutting generates a large amount of heat.  Hot surfaces and 
materials in work area can cause serious burns.  Use gloves and pliers when touching or moving 
materials in the work area. 

 

SAFETY MARK:  This equipment is suitable for supplying power for cutting operations carried out in 
an environment with increased hazard of electric shock. 

 

EQUIPMENT WEIGHT OVER 30kg:  Move this equipment with care and with the help of another 
person.  Lifting may be dangerous for your physical health. 

 

CYLINDER MAY EXPLODE IF DAMAGED:  Use only compressed gas cylinders containing the 
correct shielding gas for the process used and properly operating regulators designed for the gas and 
pressure used.  Always keep cylinders in an upright position securely chained to a fixed support.  Do 
not move or transport gas cylinders with the protection cap removed.  Do not allow the torch, work 
clamp or any other electrically live part to touch a gas cylinder.  Gas cylinders must be located away 
from areas where they may be subjected to physical damage or the cutting process including sparks 
and heat sources. 

   

   

   

 

Cutting sparks can cause explosion or fire.  Keep 
flammables away from cutting.  Do not cut near 
flammables.  Have a fire extinguisher nearby, and 
have a watch person ready to use it.  Do not cut on 
drums or any closed container. 

Summary of Contents for INVERTEC PC208

Page 1: ...IM2016 02 2013 Rev 06 INVERTEC PC208 PC210 OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu ...

Page 2: ...C208 INVERTEC PC210 conforms to the following directives 2006 95 CEE 2004 108 CEE and has been designed in compliance with the following standards EN 60529 EN 60974 1 EN 60974 7 EN 60974 10 15 02 2013 Paweł Lipiński Operations Director Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland 07 11 ...

Page 3: ...mediately to the dealer For future reference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDEX Safety 1 Installation and Operator Instructions 2 Electromagnetic Compatibility EMC 5 Technical Specifications 6 WEEE 6 Spare Parts 7 Electrical Schema...

Page 4: ...ating this equipment CE COMPLIANCE This equipment complies with the European Community Directives ARTIFICIAL OPTICAL RADIATION According with the requirements in 2006 25 EC Directive and EN 12198 Standard the equipment is a category 2 It makes mandatory the adoption of Personal Protective Equipments PPE having filter with a protection degree up to a maximum of 15 as required by EN169 Standard WORK...

Page 5: ...a protection rating of IP23S Keep it dry when possible and do not place it on wet ground or in puddles Locate the machine away from radio controlled machinery Normal operation may adversely affect the operation of nearby radio controlled machinery which may result in injury or equipment damage Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient ...

Page 6: ...n A 5 minutes timeout stops the purge function this happens only if the Output Current Knob remains in the purge mode for a long time B Power ON OFF green LED It lights up when the machine is ON C Output red LED See meanings in the following table D Thermal yellow LED See meanings in the following table LEDs Meaning Output Red Thermal Yellow On Off The cutting torch is energized On On Part in plac...

Page 7: ...of these power sources is to have available a current which remains constant at the set value independently from the length of the plasma arc When preparing to cut make sure you have all materials needed to complete the job and have taken all safety precautions Install the machine as instructed in this manual and remember to attach the work clamp to the work piece Turn ON the Power Switch H placed...

Page 8: ... 73 68 47 25 80 6 81 6 70 25 55 58 43 25 67 70 62 8 mm 25 10 23 25 12 30 10 mm 25 20 4 25 23 6 11 mm 25 11 25 12 15 mm Electromagnetic Compatibility EMC 01 11 This machine has been designed in accordance with all relevant directives and standards However it may still generate electromagnetic disturbances that can affect other systems like telecommunications telephone radio and television or other ...

Page 9: ...personnel and equipment Shielding of cables in the work area can reduce electromagnetic emissions This may be necessary for special applications Technical Specifications INPUT Input Voltage 230 V 10 Single Phase Input Power at Rated Output EMC Class A Frequency 50Hz 2 kW 100 Duty Cycle 2 5 kW 60 Duty Cycle 3 kW 35 Duty Cycle RATED OUTPUT AT 40 C Duty Cycle Based on a 10 min period Output Current O...

Page 10: ...le below to determine where the part is located for your particular code machine Use only the parts marked X in the column under the heading number called for in the assembly page indicate a change in this printing First read the Part List reading instructions above then refer to the Spare Part manual supplied with the machine that contains a picture descriptive part number cross reference Electri...