Oven will not heat 

Gas supply 

Check for adequate gas supply to oven. 

 

Manual gas shut off valve 

Check to see that the manual gas shut off valve is 
open. Also, check flexible gas line connection for any 
damage. 

 

Main fan motor 

Check for main fan operation. If it is not operating, refer 
to “Oven fan will not run”. 

 

Relay, main fan 

Check for 208/240VAC supplied to relay terminal #13. 
If voltage is not present, trace wiring back to power 
supply. If voltage is present, check for 208/240VAC at 
terminal #14. If there is no voltage at terminal #14, and 
the relay is energized, replace the main fan relay. 

 

Air pressure switch, Main fan 
motor 

Check for 208/240VAC to the air pressure switch. If no 
voltage is present, trace wiring back to main fan switch. 
This normally open switch should close when the main 
fan is activated. Check air switch tube for blockage or 
any obstructions, repair as needed. Refer to the 
“Removal and installation” section for proper 
adjustment of air pressure switch. Replace air pressure 
switch as needed. 

 

Hi-limit thermostat, oven cavity Terminals are normally closed. If open, reset 

thermostat and retest. If thermostat will not hold for 
maximum oven temperature, and oven is not exceeding 
temperature setting, check for proper location of 
capillary bulb in its spring holder. If the capillary checks 
okay, replace the hi-limit thermostat. 

 

Transformer, burner/control 

Check for 208/240VAC supplied to primary of 
transformer. If no voltage is present, trace wiring back 
to the main fan switch. If voltage is present, check for 
24VAC at transformer secondary. 
NOTE: This is a dual secondary transformer, it is 
important to check BOTH 24VAC outputs.   
If there is primary voltage but no secondary voltage, 
replace burner/control transformer. 

 

Motor, burner blower 

Check for 208/240VAC supplied to the burner blower 
motor. If no voltage is present, trace wiring back to the 
hi-limit thermostat. If voltage is present, and the motor 
is not turning, check for opens, shorts or grounds. 
WITH POWER OFF: Check for locked rotor. 
Replace burner blower motor as needed. 

 

Air pressure switch, burner 
blower motor 

Check for 24VAC to the air pressure switch. If no 
voltage is present, trace wiring back to the 
burner/control transformer. This normally open switch 
should close when the burner blower motor is 
activated. Check air switch tube for blockage or any 
obstructions, repair as needed. Refer to the “Removal 
and installation” section for proper adjustment of air 
pressure switch. Replace air pressure switch as 
needed. 

 

Burner control 

Check for 24VAC supply to the ignition control. If no 
voltage is present, trace wiring back to centrifugal 
switch of burner blower motor. If voltage is present, 
check for 24VAC at pin #3 and ground (pilot valve). 
NOTE: The Honeywell ignition control has a 30 second 
pre-purge (time delay) built in. If voltage is not present, 
replace ignition control. If the pilot valve is energized, 
check to see that the high voltage igniter circuit is also 
energized. To check, turn power off, disconnect the 
igniter lead from the ignition control. Turn power on. If 
no spark is visible, replace burner control. If a spark is 
visible at burner control, proceed.  

 

Pilot valve 

Check for 24VAC supplied to pilot valve. If no voltage is 

https://appliancetechmanuals.com

Summary of Contents for Impinger X2 Ovens with Push Button Controls 3240-2

Page 1: ...N CONTROLS MODEL 3240 2 3262 2 3270 2 Lincoln Foodservice Products LLC 1111 North Hadley Road Fort Wayne Indiana 46804 United States of America Phone 800 374 3004 U S Fax 888 790 8193 Int l Fax 260 43...

Page 2: ...energized and the igniter circuit is energized Ignition should now occur After the pilot flame is proven the main gas valve is energized TEMPERATURE CONTROL Closing the main fan switch supplies line v...

Page 3: ...d now occur After the pilot flame is proven the main gas valve is energized TEMPERATURE CONTROL Closing the main fan switch supplies line voltage through a filter to the oven control transformer The t...

Page 4: ...Impinger X2 Digital Service Manual Dom Int l 4 SCHEMATIC DIAGRAM MODELS 3240 2 3262 2 3270 2 60 HZ WITH PUSH BUTTON CONTROLS https appliancetechmanuals com...

Page 5: ...Impinger X2 Digital Service Manual Dom Int l 5 SCHEMATIC DIAGRAM MODELS 3262 2 3270 2 50 HZ WITH PUSH BUTTON CONTROLS https appliancetechmanuals com...

Page 6: ...no voltage is present trace wiring back to power supply Check for 208 240VAC to the coil of the main fan relay If no voltage is present trace wiring back to the 30 minute time delay relay check to be...

Page 7: ...oltage is present check for 24VAC at transformer secondary NOTE This is a dual secondary transformer it is important to check BOTH 24VAC outputs If there is primary voltage but no secondary voltage re...

Page 8: ...condary NOTE This is a dual secondary transformer it is important to check BOTH 24VAC outputs If there is primary voltage but no secondary voltage replace burner control transformer Oven control Check...

Page 9: ...over heat and then cool this will cause the units to cycle on and off intermittently Improper ventilation or lack of preventive maintenance may cause this Also most of the problems listed under Oven w...

Page 10: ...r runs but there is no speed display NOTE Display will indicate STALL Oven control Check output voltage from oven control to hall effect sensor sensor is located in conveyor motor Measure voltage at t...

Page 11: ...ace wiring back to the 30 minute time delay relay check to be sure that the Overload Protector contacts are closed If contacts are open see Overload Protector below If voltage is present check to insu...

Page 12: ...e fails replace burner control Burner reset switch Switch is normally open check to see that the switch closes when reset button is pushed Replace switch as needed Motor burner blower Check for supply...

Page 13: ...st is okay replace the burner control NOTE Flame should be on at this time Low flame is on but no main flame Transformer control Check for supply voltage to primary of control transformer If no voltag...

Page 14: ...valve as needed Intermittent heating Thermal Overload of main fan and burner blower motors The main fan motor and burner blower motor are equipped with internal thermal protection and will cease to op...

Page 15: ...switch check good replace the oven control Conveyor motor runs but there is no speed display NOTE Display will indicate STALL Oven control Check output voltage from oven control to hall effect sensor...

Page 16: ...motor and motor mount assembly Remove motor from motor mount Remove pulley from motor and install pulley on new motor 6 Reassemble in reverse order and check system operation Be sure to check for prop...

Page 17: ...e shaft through idle end of oven 13 NOTE When putting new shaft and blower wheels back in the wheels will have to be removed from the shaft It is important to mark the blowers left and right and to ma...

Page 18: ...power at main breaker 2 Remove control box cover 3 Disconnect wiring from switch and mark all wiring for reassembly 4 Remove switch by depressing spring clips on sides of switch Push switch out 5 Reas...

Page 19: ...eded AIR PRESSURE SWITCH BURNER MOTOR ADJUSTMENT To adjust the air pressure switch remove snap on cover on the side of the switch to expose adjusting screw To increase sensitivity turn screw counter c...

Page 20: ...d piping assembly 6 Remove piping from old valve and reassemble in reverse order 7 Check all gas line fittings for leaks and adjust manifold pressure on gas valve Refer to the specification plate on t...

Page 21: ...n REVERSING SWITCH REPLACEMENT 1 Shut off power at main breaker 2 Remove control box cover Remove reversing switch cover 3 Disconnect wiring from reversing switch and mark all wiring for reassembly 4...

Page 22: ...ake time and oven temperature Set Point Menu A Press and hold the 2 LH buttons to enter Set Point program Once in Set Point program press TEMP button and adjust temperature using up or down arrows Pre...

Page 23: ...nd 4 are OFF Bottom Back Belt Dip Switch 4 will be ON and 1 2 and 3 are OFF CONVEYOR CONTROL REPLACEMENT 1 Shut off power at main breaker 2 Remove control box cover 3 Remove wiring from appropriate co...

Page 24: ...FOR DOOR OPTIONS O 2805112 Nameplate Impinger X2 P SEE PAGE 31 FOR DOOR OPTIONS 100302900 Caster 5 Q 100303000 Caster 5 w brake 300202036 Bottom finger support 3240 100202036 Bottom finger support 326...

Page 25: ...Impinger X2 Digital Service Manual Dom Int l 25 https appliancetechmanuals com...

Page 26: ...1280 Extension tube burner 3240 100601280 Extension tube burner 3262 I 200601280 Extension tube burner 3270 300601328 Shaft blower wheel assy 3240 100601328 Shaft blower wheel assy 3262 J 200601328 Sh...

Page 27: ...Impinger X2 Digital Service Manual Dom Int l 27 https appliancetechmanuals com...

Page 28: ...itch 60 Hz 60 Hz Model Only Q 370541 On Off Switch 50 Hz 50 Hz Model Only R 390089 Digital Control Board S 370360 Capacitor 230V Digital T 390090 Control Conveyor U 501070EP Air Pressure Switch 508202...

Page 29: ...Impinger X2 Digital Service Manual Dom Int l 29 https appliancetechmanuals com...

Page 30: ...or main fan 3HP 1 Phase 50 Hz Model Only Vendor 35V424Q013G1 Gates 6929 V Belt 21 32 x 29 Lincoln Part 390128 Motor main fan 3HP 3 Phase 50 Hz Model Only Vendor 35V426Y886G1 Baldor Motor P N M3161TA L...

Page 31: ...3262 200801140 1 Door Solid Model 3270 300801140 Old Style Door w single sandwich door Model 3240 100801140 Old Style Door w single sandwich door Model 3262 200801140 Old Style Door w single sandwich...

Page 32: ...t I J 390099 Cable spark 60 Hz Model Only 390115 Orifice Pilot Nat 60 Hz Model Only 369073 Orifice Pilot Nat 50 Hz Model Only 390098 Orifice Pilot L P 60 Hz Model Only K 390125 Orifice Pilot L P 50 Hz...

Page 33: ...Impinger X2 Digital Service Manual Dom Int l 33 https appliancetechmanuals com...

Page 34: ...3262 E 100405830 Conveyor belt complete 3270 405830 1EP Conveyor belt 1ft section F 390051 Bushing assembly single belt G 100404710 Shaft idle end H 406000EP Roller smooth I 405900EP Roller notched 30...

Page 35: ...Impinger X2 Digital Service Manual Dom Int l 35 https appliancetechmanuals com...

Page 36: ...lt complete 3262 E 100405844 Conveyor belt complete 3270 405849 1EP Conveyor belt 1ft section F 390050 Bushing assembly dual belt G 100404710 Shaft idle end H 406000EP Roller smooth I 405900EP Roller...

Page 37: ...Impinger X2 Digital Service Manual Dom Int l 37 https appliancetechmanuals com...

Page 38: ...Impinger X2 Digital Service Manual Dom Int l 38 This page intentionally left blank https appliancetechmanuals com...

Page 39: ...Impinger X2 Digital Service Manual Dom Int l 39 This page intentionally left blank https appliancetechmanuals com...

Page 40: ...Impinger X2 Digital Service Manual Dom Int l 40 https appliancetechmanuals com...

Reviews: