Error
Code#
713
714
715
719
Description
Input Power Misconnect.
Supply Voltage is too high.
Input Power Misconnect.
Supply Voltage is too low.
Under Voltage Lockout.
Switch PCB Error.
Occurs upon power up when the supply
voltage to the switch pcb exceeded accept-
able levels.
Occurs upon power up when the supply
voltage to the switch pcb is below accept-
able levels.
The supply voltage to the switch pcb is
below acceptable levels
Verify the primary reconnect
is properly configured for the
input voltage.
Machine needs to be turned
off and back on to reset.
Verify the primary reconnect
is properly configured for the
input voltage.
Machine needs to be turned
off and back on to reset.
Machine needs to be turned
off and back on to reset.
Machine needs to be turned
off and back on to reset.
FLEXTEC™ 450 Fault Codes
Corrective Action
Possible Cause
If any of these conditions persist contact an authorized Lincoln Field Service Shop.
(For Code 11941 and above)
Summary of Contents for FLEXTEC 450
Page 39: ...F 5 DIMENSION PRINT F 5 FLEXTEC 450 L15698 A 01 26 66 18 78 14 14 26 51 13 06 ...
Page 40: ...FLEXTEC 450 NOTES ...
Page 42: ...08 15 2012 FLEXTEC 450 P 652 A P 652 A ILLUSTRATION OF SUB ASSEMBLIES 5 4 1 2 3 ...
Page 47: ...FLEXTEC 450 NOTES ...
Page 56: ...FLEXTEC 450 NOTES ...
Page 58: ...02 04 2013 FLEXTEC 450 P 732 A P 732 A ILLUSTRATION OF SUB ASSEMBLIES 5 4 1 2 3 ...
Page 70: ...FLEXTEC 450 NOTES ...
Page 71: ...FLEXTEC 450 NOTES ...