Lincoln 981 Installation And Maintenance Manual Download Page 2

 

Systems which will be dispensing fluids 
under pressure may need to be protect-
ed by using a thermal relief kit, which 
will safely limit the pressures caused by 
thermal expansion.  Please contact your 
local Lincoln distributor and refer to 
Service Page Section K5, Page 31 for 
more details. Failure to include thermal 
relief protection may cause damage not 
covered under Lincoln’s warranty policy.

W A R N I N G

General

The Lincoln electronic lube meter is  
designed spe cifically to dispense motor oils 
(SAE 5-50), gear oils (SAE 80-240), auto-
matic transmission fluid, antifreeze (Ethyl-
ene glycol), brake fluid, engine cool ant, and 
windshield wiper fluid solutions. Modular 
design, low cost, lightweight and rugged  
design make the model 981 the best choice 
for overhead reel systems.

The electronic register mo dule contains  

a micro processor powered by a lithium bat-
tery. It can be pro   grammed to dispense in 
pints, quarts, liters, or gal  lons and will total-
ize in liters or gallons. The meter calibration 
factor is determined during factory test. The 
meter can be recalibrated in the field for flu-
ids of different viscosity. A six-digit liquid 
crystal display, accurate to the second deci-
mal place, shows the exact amount of fluid 
dispensed. The electronic-register, module 
housing is made of shock-resistant nylon 
that is protected by a rubber boot to handle 
the harshest of environments.

Please ensure that all fluid is properly 
filtered before it enters the meter.

Foreign particles in the meter could 

cause inaccurate meter readings, and 
could possibly damage the meter.

C A U T I O N

Operation

As fluid passes through the metering cham-
ber by entering the inlet port, it forces the 
internal gears to rotate and exits through 
the outlet port. Each rotation of the gear 
displaces a given volume of fluid. 

The display shows the amount of fluid 

dispensed since the last time the reset but-
ton was pushed. Pushing the reset button 
will reset the display to zero for the next 
dispense.

To change the unit of measure:

Press the TOTAL button three times, fol-
lowed by the RESET button three times 
within a time frame of two seconds. The 
active unit of measure symbol begins 
flashing, indicating that you are in pro-
gramming mode.

Press the RESET button repeatedly until 
the desired unit of measure appears 
flashing in the display.

Simultaneously press and hold the RESET 
button and the TOTAL button for about 
three seconds to enter the new unit of 
measure and exit programming mode.

Meter is not for resale measurement of fluid.

Features

•  1,500 psi 

(103.5 bar)

 pressure rating.

•  Max flow rate 10 gal./m 

(38 l/m)

.

•  Large six-digit LCD display with two deci-

mal point precision.

•  Dispense total display in pints, quarts, 

gallons or liters.

•  Unit of measure selectable from the front 

of register.

•  Totalization in gallons and liters.
•  Re-settable and non-re-settable totalizer
•  Display operation temperature range  

–4 to 140 °F 

(

20

 

to

 

60 °C)

.

•  Low-battery indicator
•  Long-life, field-replaceable, top-loading 

battery

•  Accuracy of ±0.5 percent
•  Calibration factor programmable from 

front of register

•  Calibration factor saved in nonvolatile 

memory

•  Rigid spout with automatic tip

Note: 

The display remains ON and does not 

affect the life of the battery

2

Summary of Contents for 981

Page 1: ...guide Read manual prior to installation or use of this product Keep manual nearby for future reference Failure to follow instructions and safety precautions may result in death or serious injury DAN G ER Date of issue February 2015 Form number 404531C Section F22 Page 36C ...

Page 2: ...curate meter readings and could possibly damage the meter C AUT I O N Operation As fluid passes through the metering cham ber by entering the inlet port it forces the internal gears to rotate and exits through the outlet port Each rotation of the gear displaces a given volume of fluid The display shows the amount of fluid dispensed since the last time the reset but ton was pushed Pushing the reset...

Page 3: ...e mode Exploded view 3 1 2 Parts Item Description Part no 1 Housing cover kit with screws standard 276920 2 Gear service kit with o ring standard 272377 3 Register module with screws 276921 4 Rubber boot not shown 276922 5 Control handle not shown 276924 6 Rigid spout with automatic tip not shown 282842 7 Replacement battery 3 V lithium 2 3 AA not shown 276923 Apply Meter to Hose Close the drain v...

Page 4: ...Pressure drop Note This chart repre sents pressure vs flow rate for the complete meter assembly The test fluid was DTE 25 hydraulic oil at 75 F 24 C 4 ...

Page 5: ...This page left intentionally blank 5 ...

Page 6: ...This page left intentionally blank 6 ...

Page 7: ...772 85782 and replacement injectors 85771 85781 Lincoln warrants the SL V Injector series to be free from defects in material and work manship for two 2 years following the date of purchase If an injector model single or replacement is determined to be defective by Lincoln in its sole discretion during this warranty period it will be repaired or replaced at Lincoln s discretion without charge Spec...

Page 8: ... equipment reliabil ity optimizing operational and energy efficiency and reducing total cost of ownership These competence areas include bearings and units seals lubrication systems mechatronics and a wide range of services from 3 D computer modelling to cloud based condition monitoring and asset management services SKF s global footprint provides SKF customers with uniform quality standards and w...

Reviews: