Page Number - 2
Form 403846
Models 84918 and 84919
POWER-MASTER III TRANSFER PUMPS
Shovel Type Foot Valve
OWNER/OPERATOR RESPONSIBILITY
It is the responsibility of the Owner/Operator to properly use and maintain this equipment.
The Instructions and Warnings contained in this manual shall be read and understood by the Owner/Operator prior to operating
this equipment
It is the responsibility of the Owner/Operator to maintain the legibility of all Warning and Instruction labels
The Owner/Operator shall retain this manual for future reference to important Warnings, Operating and Maintenance
Instructions.
DO NOT operate these pumps with 10” or 8” airmotor.
DO NOT exceed the stated maximum working pressure of the airmotor or the lowest rated component in your system.
DO NOT alter or modify any part of this equipment.
DO NOT operate this equipment with combustible gas.
DO NOT attempt to repair or disassemble the equipment while the system is pressurized.
TIGHTEN all fluid connections securely before using this equipment.
ALWAYS read and follow the fluid manufacturer’s recommendations regarding fluid compatibility, and the use of protective
clothing and equipment.
CHECK all equipment regularly and repair or replace worn or damaged parts immediately.
THESE PUMPS ARE FOR MATERIAL TRANSFER APPLICATIONS ONLY!
IMPORTANT: Failure to heed these warnings including misuse, over pressurizing, modifying parts, using incompatible
chemicals and fluids, or using worn or damaged parts, may result in equipment damage and/or serious personal injury, fire,
explosion, or property damage.
PUMP TUBE SPECIFICATIONS
Pump Stroke – 6 in. (152 mm)
Output per cycle – 10.9 cu. in. (179 cc)
Max. recommended speed (continuous) – 75 cycles/min.
Approx. cycles per gallon (liter) – 21 (5.5)
Output at 75 cycles/min. – 3.5 gpm (13.2 liter/min.)
Wetted part materials – Steel, Brass, Copper, Polyurethane, Nitrile
To order call 1-800-548-1191 or visit www.partdeal.com - [email protected]