![Lincoln 1154-080-EA Installation And Parts & Service Manual Download Page 10](http://html1.mh-extra.com/html/lincoln/1154-080-ea/1154-080-ea_installation-and-parts-and-service-manual_1917648010.webp)
Impinger II – Advantage Digital Express Service Manual - International
10
TROUBLESHOOTING GUIDE
IMPINGER II ADVANTAGE DIGITAL EXPRESS
SERIES
1164
EXPORT
400/230VAC
50HZ.
3
PHASE
REFER TO PROPER SCHEMATIC FOR IDENTIFIED COMPONENTS
SYMPTOM
POSSIBLE CAUSE
EVALUATION
Oven fan will not run
Incoming power supply
Check breaker, reset if required. Check power plug to
be sure it is firmly in receptacle. Measure incoming
power, call power co. if needed.
Oven cavity hi-limit
thermostat
Terminals are normally closed, opens at 660
°
F (350
°
C).
If open, reset and test oven for proper operation. If
thermostat will not hold for maximum oven temperature,
and oven is not exceeding control setting, check for
proper location of capillary bulb ion its spring holder. If
above checks are okay, replace hi-limit thermostat.
Fuse, 10 amp
Check, replace if necessary.
Fuse holder
Check, replace if necessary.
Switch, main fan
With power off, check continuity between switch
terminals. Replace as needed.
Motor, main fan
Check for opens, shorts or grounds. With power off, turn
fan blade to check for locked rotor.
Capacitor
Check for shorts or grounds.
WARNING: Capacitor has a stored charge, discharge
before testing.
No control box cooling
Incoming power supply
Check breaker, reset if required. Check power plug to
be sure it is firmly in receptacle. Measure incoming
power, call power co. if needed.
Oven cavity hi-limit
thermostat
Terminals are normally closed, opens at 660
°
F (350
°
C).
If open, reset and test oven for proper operation. If
thermostat will not hold for maximum oven temperature,
and oven is not exceeding control setting, check for
proper location of capillary bulb in its spring holder. If
above checks are okay, replace hi-limit thermostat.
Fuse, 10 amp
Check, replace if necessary.
Fuse holder
Check, replace if necessary.
Switch, main fan
With power off, check continuity between switch
terminals. Replace as needed.
Cooling fan
Line voltage should now be at the cooling fan. If voltage
is present, check motor for opens, shorts or grounds.
With power off, check for locked rotor.
No automatic control
box cooling
Incoming power supply
Check breaker, reset if required. Check power plug to
be sure it is firmly in receptacle. Measure incoming
power, call power co. if needed.
Oven cavity hi-limit
thermostat
Terminals are normally closed, opens at 660
°
F (350
°
C).
If open, reset and test oven for proper operation. If
thermostat will not hold for maximum oven temperature,
and oven is not exceeding control setting, check for
proper location of capillary bulb ion its spring holder. If
above checks are okay, replace hi-limit thermostat.
Fuse, 10 amp
Check, replace if necessary.
Fuse holder
Check, replace if necessary.
Cooling fan thermostat
Check the cooling fan thermostat (thermostat closes at
120
°
F and opens at 100
°
F). With the cooling fan
thermostat pre-heated, check for continuity. If
thermostat is open, replace cooling fan thermostat.
Cooling fan
Line voltage should now be at the cooling fan. If voltage
is present, check motor for opens, shorts or grounds.
With power off, check for locked rotor.