E-4
TROUBLESHOOTING
WELD-PAK 100
Observe Safety Guidelines
detailed in the beginning of this manual.
TROUBLESHOOTING GUIDE
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
LOCAL AUTHORIZED LINCOLN ELECTRIC FIELD SERVICE FACILITY
for assistance before you proceed.
CAUTION
PROBLEMS
(SYMPTOMS)
Arc is unstable – Poor starting
POSSIBLE AREAS OF
MISADJUSTMENT(S)
1. Check for correct input voltage
to machine – 115vac.
2. Check for proper electrode
polarity for process.
3. Check gun tip for wear or dam-
age and proper size – Replace.
4. Check for proper gas and flow
rate for process. (For MIG only.)
5. Check work cable for loose or
faulty connections.
6. Check gun for damage or
breaks.
7. Check for proper drive roll orien-
tation and alignment.
8. Check liner for proper size.
RECOMMENDED
COURSE OF ACTION
Contact your local Lincoln
Authorized Field Service Facility.
WELDING PROBLEMS
Summary of Contents for WELD-PAK 100 PLUS
Page 8: ...WELD PAK 100 vii...
Page 32: ...WELD PAK 100 B 18 APPLICATION CHART...
Page 34: ...C 2 NOTES WELD PAK 100...
Page 40: ...D 6 NOTES WELD PAK 100...
Page 46: ...F 2 NOTES WELD PAK 100...
Page 55: ...NOTES SQUARE WAVE TIG 255...
Page 56: ...NOTES SQUARE WAVE TIG 255...