Lincoln Electric SPEEDTEC 215C AUS Operator'S Manual Download Page 17

English 15 English 

WEEE 

07/06 

 

Do not dispose of electrical equipment together with normal waste! 
In observance of European Directive 2012/19/EC on Waste Electrical and Electronic Equipment (WEEE) 
and its implementation in accordance with national law, electrical equipment that has reached the end of its 
life must be collected separately and returned to an environmentally compatible recycling facility.  As the 
owner of the equipment, you should get information on approved collection systems from our local 
representative. 
By applying this European Directive you will protect the environment and human health! 

 

Spare Parts 

12/05 

Part List reading instructions 

  Do not use this part list for a machine if its code number is not listed.  Contact the Lincoln Electric Service Department 

for any code number not listed. 

  Use the illustration of assembly page and the table below to determine where the part is located for your particular 

code machine. 

  Use only the parts marked "X" in the column under the heading number called for in the assembly page (# indicate a 

change in this printing). 

 
First, read the Part List reading instructions above, then refer to the "Spare Part" manual supplied with the machine, that 
contains a picture-descriptive part number cross-reference. 
 

REACh 

11/19 

Communication in accordance with Article 33.1 of Regulation (EC) No 1907/2006 – REACh. 

Some parts inside this product contain: 
Bisphenol A, BPA, 

 

EC 201-245-8, CAS 80-05-7 

Cadmium, 

 

 

EC 231-152-8, CAS 7440-43-9 

Lead, 

 

 

 

EC 231-100-4, CAS 7439-92-1 

Phenol, 4-nonyl-, branched, 

EC 284-325-5, CAS 84852-15-3 

in more than 0,1% w/w in homogeneous material. These substances are included in the “Candidate List of Substances of 
Very High Concern for Authorisation” of REACh. 
Your particular product may contain one or more of the listed substances. 
Instructions for safe use: 

  use according to Manufacturer instructions, wash hands after use; 

  keep out of reach of children, do not put in mouth, 

  dispose in accordance with local regulations. 

 

Authorized Service Shops Location 

09/16 

  The purchaser must contact a Lincoln Authorized Service Facility (LASF) about any defect claimed under Lincoln's 

warranty period. 

  Contact your local Lincoln Sales Representative for assistance in locating a LASF or go to 

www.lincolnelectric.com/en-

gb/Support/Locator.

 

 

Electrical Schematic 

 
Refer to the "Spare Part" manual supplied with the machine. 

Summary of Contents for SPEEDTEC 215C AUS

Page 1: ...IM3065 10 2020 REV02 SPEEDTEC 215C AUS OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 260 Bielawa Poland www lincolnelectric eu ...

Page 2: ...ord in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDEX Technical Specifications 1 Electromagnetic Compatibility EMC 2 Safety 3 Introduction 5 Installation and Operator Instructions 5 WEEE 15 Spare Parts 15 REACh 15 Authorized Service Shops Location 15 El...

Page 3: ...MAW 51 Vdc 100 75A 17 7 Vdc 40 100A 19 Vdc FCAW SS 51 Vdc 100 75A 17 7 Vdc 40 100A 19 Vdc SMAW 11 Vdc 100 60A 22 4 Vdc 40 80A 23 2 Vdc GTAW 11 Vdc 100 90A 13 6 Vdc 40 125A 15 Vdc WELDING CURRENT RANGE GMAW FCAW SS SMAW GTAW 230Vac 20A 200A 20A 200A 20 160A 20A 160A 115Vac 20A 100A 20A 100A 20 80A 20A 125A RECOMMENDED INPUT CABLE AND FUSE SIZES Fuse or Circuit Breaker Size Power Lead B 16A B 25A 3 ...

Page 4: ...ocesses Equipment for calibration and measurement Personal medical devices like pacemakers and hearing aids Check the electromagnetic immunity for equipment operating in or near the work area The operator must be sure that all equipment in the area is compatible This may require additional protection measures The dimensions of the work area to consider will depend on the construction of the area a...

Page 5: ...ccordance with local electrical regulations ELECTRICALLY POWERED EQUIPMENT Regularly inspect the input electrode and work clamp cables If any insulation damage exists replace the cable immediately Do not place the electrode holder directly on the welding table or any other surface in contact with the work clamp to avoid the risk of accidental arc ignition ELECTROMAGNETIC FIELD MAY BE DANGEROUS Ele...

Page 6: ...ielding gas for the process used and properly operating regulators designed for the gas and pressure used Always keep cylinders in an upright position securely chained to a fixed support Do not move or transport gas cylinders with the protection cap removed Do not allow the electrode electrode holder work clamp or any other electrically live part to touch a gas cylinder Gas cylinders must be locat...

Page 7: ...mal operation may adversely affect the operation of nearby radio controlled machinery which may result in injury or equipment damage Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient temperature greater than 40 C Input Supply Connection WARNING Only a qualified electrician can connect the welding machine to the supply network Installation had ...

Page 8: ...the mains supply before turning power on I After input power is connected and the power switch is turned on the indicator will light up to indicate the machine is ready to weld 8 Escape Button right Cancels an action exit menu Locks and unlocks knobs and buttons on the panel press and hold button for 4 seconds 9 Set Knob Type of welding procedure and welding settings is changed by this knob 10 Rig...

Page 9: ...racket for gas bottle 230mm SP215C Provides the possibility of mounting cylinders with a diameter 230 mm see Gas Connection section WARNING Positive polarity is set at the factory WARNING Before welding check the polarity for using electrodes and wires If the welding polarity has to be changed user should Switch off the machine Determine the wire polarity for the wire to be used Consult the electr...

Page 10: ...English 8 English Table 1 Positive polarity factory setting Table 2 Negative polarity WORK LEAD WORK LEAD ...

Page 11: ...stment of pressure arm gives the best welding performance WARNING If the roll pressure is too low the roll will slide on the wire If the roll pressure is set too high the wire may be deformed which will cause feeding problems in the welding gun The pressure force should be set properly Decrease the pressure force slowly until the wire just begins to slide on the drive roll and then increase the fo...

Page 12: ...t 4 Depending on the using wire connect the work lead 19 to output socket 5 or 6 See 16 point terminal block of changing polarity Connect the work lead to the welding piece with the work clamp Install the proper wire Install the proper drive roll Make a sure if it is needed GMAW process that the gas shield has been connected Turn the machine on Push the gun trigger to feed the wire through the gun...

Page 13: ... prepares the end of the wire for the next arc start Run in WFS sets the wire feed speed from the time the trigger is pulled until an arc is established Spot Timer adjusts the time welding will continue even if the trigger is still pulled This option has no effect in 4 Step Trigger Mode Adjusting range WARNING Spot Timer has no effect in 4 Step Trigger Mode Preflow Time adjusts the time that shiel...

Page 14: ... The welding machine is now ready to weld WARNING Do not kink or pull cable around sharp corners By applying the principle of occupational health and safety at welding welding can be begun During welding GTAW process the user can set function Basic menu Advanced menu The welding current Switch on switch off the output voltage on the output lead The welding current Switch on switch off the output v...

Page 15: ...cel an Action Inductance Select Gas Switch On Output Voltage TIG MMA only Spot Welding Setting Select Wire Type material Switch Off Output Voltage TIG MMA only Spot Timer Select Wire Size diameter Unlock panel Switch off Spot Welding Select Function of Gun Trigger 2 Step 4 Step Unlock Panel by Code 2 Step Configuration and Set up Hot Start 4 Step Lock Unlock Panel Arc Force Memory Lock Panel Adjus...

Page 16: ... be disconnected from the machine before each maintenance and service After each repair perform proper tests to ensure safety Customer Assistance Policy The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment consumables and cutting equipment Our challenge is to meet the needs of our customers and to exceed their expectations On occasion purchasers ...

Page 17: ... First read the Part List reading instructions above then refer to the Spare Part manual supplied with the machine that contains a picture descriptive part number cross reference REACh 11 19 Communication in accordance with Article 33 1 of Regulation EC No 1907 2006 REACh Some parts inside this product contain Bisphenol A BPA EC 201 245 8 CAS 80 05 7 Cadmium EC 231 152 8 CAS 7440 43 9 Lead EC 231 ...

Page 18: ...English 16 English Quick Guide ...

Page 19: ...English 17 English ...

Page 20: ...English 18 English ...

Page 21: ...IT 200A 25 3M Lead s KIT to SMAW process The electrode holder with lead to SMAW process 3m Work lead 3m R 0010 450 1R Protective screen LE250RG002 Gas Regulator K14330 1 BRACKET FOR GAS BOTTLE 230mm SP215C Drive rolls to 2 driven rolls Solid wires KP14016 0 8 V0 6 V0 8 KP14016 0 9 V0 9 V1 0 KP14016 1 0 V0 8 V1 0 Aluminum wires KP14016 0 9A U0 9 U1 2 KP14016 1 2A U1 0 U1 2 Cored wires KP14016 1 1R ...

Reviews: