![Lincoln Electric SP-175T Operator'S Manual Download Page 8](http://html.mh-extra.com/html/lincoln-electric/sp-175t/sp-175t_operators-manual_1918661008.webp)
A-1
SP-175T
A-1
INSTALLATION
Fuse or
Output Mode
Input Voltage
Breaker Size
Input Amps
Power Cord
RATED
230V/60Hz
40 Super Lag
20/22
50 Amp, 250V,
208V/60Hz
Three-Prong Plug
(NEMA Type 6-50P)
TECHNICAL SPECIFICATIONS – SP-175T
INPUT – SINGLE PHASE ONLY
RATED OUTPUT
OUTPUT
RECOMMENDED INPUT CABLE AND FUSE SIZES
Height
Width
Depth
Weight
12.0 in
9.75 in
16.5 in
57 Ibs
305 mm
248 mm
419 mm
25.9 kg
PHYSICAL DIMENSIONS
Standard Voltage/Frequency
Input Current
230V/60Hz
20 Amps – Rated Output
208V/60Hz
22 Amps – Rated Output
Duty Cycle
Amps
Volts at Rated Amperes
30% Duty Cycle @ 230V/60Hz
130
20
25% Duty Cycle @ 208V/60Hz
130
20
Welding Current Range
Maximum Open Circuit Voltage
Wire Speed Range
Rated DC Output: 30 – 175 amps
33
50-400IPM (1.3-10.2m/min)
Summary of Contents for SP-175T
Page 20: ...B 7 B 7 APPLICATION CHART SP 175T ...
Page 32: ...NOTES SP 175T ...
Page 33: ...NOTES SP 175T ...