![Lincoln Electric Semiautomatic Wire Feeders LN-9 Service Manual Download Page 51](http://html.mh-extra.com/html/lincoln-electric/semiautomatic-wire-feeders-ln-9/semiautomatic-wire-feeders-ln-9_service-manual_1918633051.webp)
GUN AND CABLE MAINTENANCE
For instructions on periodic maintenance for the weld-
ing gun and cables, refer to the manual for your specif-
ic model of welding gun. Also see IM-294.
GUN CABLE CONNECTOR
REQUIREMENTS TO PERMIT PROPER
CONNECTION TO LINCOLN LN-9 AND
LN-9F WIRE FEEDER
The following Figures D.1 and D.2 should serve as a
guide to determine if a particular gun or switch can be
connected to the LN-9 and LN-9F models.
“A” Diameter Hole
to be Concentric to
Wire Size
.749/.747 Dia.
Within .008 F.I.M.
7/64 & .120"
.152 (#24 Drill)
.068 Thru 3/32"
.125 (1/8 Drill)
1/16 or .062"
.078 (5/64 Drill)
.045 & .052"
.062 (1/16 Drill)
.030 & .035"
.055 (#54 Drill)
All dimensions in inches and (millimeters).
1/2 Amp AC 24 Volts — Inductive
1/2 Amp DC 24 Volts — Inductive
MAINTENANCE
D-3
D-3
LN-9 Wire Feeder
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
FIGURE D.1 – LN-9 CONNECTORS
LN-9 CONNECTOR FOR 1/16-120” (1.6-3.0 MM) WIRE)
FIGURE D.2 – SWITCH REQUIREMENTS
LN-9 CABLE CONNECTOR FOR .030-.052” (0.8-1.3 mm)
WIRE (FOR ALL OTHER DIMENSIONS, SEE DIAGRAM
ABOVE).
NOTE: Connector part with .7459/.747 (19.0/18.9)
diameter should be made from brass if it is to be part
of the welding current carrying circuit.