A-1
INSTALLATION
POWER WAVE
®
E500
TECHNICaL SPECIFICaTIONS
AGENCY APPROVALS
MODEL
CONFORMITY MARK
NOTES
K3457-1
CCC
GB15579.1-2013
K3457-1 with K3129-2
Filter Kit
CE, C-Tick
IEC60974-1
IEC 60974-10 Class A
POWER SOURCES - INPUT VOLTAGE AND CURRENT
Model
Duty Cycle
Input Voltage ± 10%
Input Amperes
Idle Power (W)
Power Factor
K3457-1
60% rating
100% rating
380 / 400-415 / 3 / 50 / 60
37 / 35
150W Fan on
70W Fan off
85%
31 / 30
POWER SOURCES - RECOMMENDED INPUT WIRE AND FUSE SIZES1
Voltage
Input Amperes
(100% Rating)
Time Delay Fuse
or Breaker Size
Type 75C Copper Wire in
Conduit AWG (IEC) Sizes
40C (104°F) Ambient
Type 75C Copper
Ground Wire in Conduit
AWG (IEC) Sizes
Cord Size
AWG Sizes
(IEC)
380/3/60/50
31 A
50
10 (6)
10 (6)
8 (8)
400-415/3/60/50
30 A
50
10 (6)
10 (6)
8 (8)
RATED OUTPUT
Process
Duty Cycle
Volts at Rated
Amperes
Amperes
Efficiency
(at Rated Output)
GMAW (CV)
FCAW-G
60%
39 V
500 A
89%
100%
36.5 V
450 A
GMAW-P (CV)
60%
39 V
500 A
100%
36.5 V
450 A
PHYSICAL DIMENSIONS
MODEL
HEIGHT
WIDTH
DEPTH
WEIGHT
K3457-1
18.8 in (477 mm)
14 in (356 mm)
26.5 in (673 mm)
126 lbs. (57.1 kg)
TEMPERATURE RANGES
Operating Temperature
14° F to 131° F (-10° C to 55° C)*
Storage Temperature
-40° F to 185° F (-40° C to 85° C)
Insulation Class
Class H (180° C)
*Output is derated for temperatures in excess of 40° C (104° F).