![Lincoln Electric RANGER GXT Operator'S Manual Download Page 21](http://html.mh-extra.com/html/lincoln-electric/ranger-gxt/ranger-gxt_operators-manual_1918596021.webp)
B-5
OPERATION
B-5
RANGER GXT
SUMMARY OF WELDING PROCESSES
CONTROL ELECTRODE
CABLE IDLE WHEN NOT TO START
PROCESS USED MODE WELDING WELDING
STICK
No
AUTO
Hot
Touch electrode to work.
Welding starts immediately
and engine goes to high
idle.
WIRE FEED, LN-25 WITH
No
AUTO
Cold
Press gun trigger, LN-25
INTERNAL CONTACTOR
contactor closes. Welding
starts immediately and
engine goes to high idle.
NOTE: Output Control
must be set above
“
3
”
TIG, TIG MODULE WITH
Yes
High
Cold
Press Amptrol,
WITH CONTACTOR KIT
contactor closes,
CONTROL CABLE, &
welding starts immediately.
AMPTROL
WIRE FEED, LN-15
No
High
Cold
Press gun trigger.
ACROSS the ARC
LN-15 contactor closes,
(has internal contactor)
Welding starts immediately
Note
: Output Control must
be set above
“
3
”
.
Summary of Contents for RANGER GXT