background image

Precision TIG

®

225

[ 3 ]

“Set It/See It” Pulse Control —

Make attractive and consistent welds!

What Is It?

Pulse welding systems vary weld current between peak (high heat) and
background current (low heat) levels. Adjusting the pulse frequency
controls the level of heat input applied to the weld relative to the weld
travel speed. For the Precision TIG

®

225, pulse frequency can be varied

from 0.1 to 20 pulses per second.

Results

Better control of heat input in the weld, resulting in:

• Reduced warping and burnthrough on thin materials.   

• Smaller heat-affected zone. 

• Smaller bead profile without compromising proper penetration.

Great For

Thin materials 

– Faster pulse settings help to narrow the bead

profile and minimize the heat-affected zone and resulting warping 
or burnthrough.  

• Consistent appearance

– Slower pulse settings aid in timing the

application of filler metal to produce the consistent stacked bead
appearance associated with high quality TIG 
welding.

Maintaining a steady welding rhythm.

Easy Operation:

• Flashing indicator light lets you see the 

pulse rate before you strike an arc.  

W

el

d

in

g

 c

ur

re

nt

Peak

Background

pulsE FrEquEncy:

number of pulses per second

Time

High Heat

(Peak)

Low Heat

(Background)

Pulsed TIG Weld

(at 60 amps) 

Standard TIG Weld

(at 60 amps) 

Smaller Heat 

Affected Zone

Smaller Heat 

Affected Zone

Smaller Bead Profile

Smaller Bead Profile

AC Auto Balance

®

Controls —

Automatically sets the optimal cleaning vs. penetration
level for aluminum welding! 

What Is It?

When aluminum welding, the positive (+) portion of the AC welding
amperage cleans the oxides from the aluminum surface. The negative (-)
portion delivers more heat input, increasing penetration level.

Patented AC Auto Balance

®

automatically sets the ratio

of 

cleaning action (+) versus penetration (-) based on amperage.

Manual balance control

provides the flexibility to customize 

the arc to your preference.  

Easy Operation:

• Set it and forget it or override when you choose to customize 

the settings.  

More Cleaning (+)

Less Cleaning (+)

Less Penetration(-)

More Penetration (-)

W

E

ld

In

g

A

M

p

E

r

A

g

E

W

E

ld

In

g

A

M

p

E

r

A

g

E

TIME

TIME

Maximum Cleaning Setting

Maximum Penetration

Setting

Auto-Balance Setting

A CLOSER LOOK

Reviews: