B-9
OPERATION
POWER WAVE
®
R450
COnFIgurIng an addItIOnaL dIsPLay
By default, the display will show welding amperage and voltage
during welding. It is possible to choose an additional value to be
displayed. When an additional value is enabled, the display will
show amperage and voltage for five seconds, then the chosen
value for five seconds.
To choose an additional value, use the Selection KNOB to select
ALT DISP from the User Configuration menu and press the Right
BUTTON. Then use the Selection KNOB to select the desired
alternative value to display.
Press the Right BUTTON to enter the ALT DISP menu, then use the
Selection KNOB to find the value to display. Press the Right
BUTTON again to select the value, or the left BUTTON to cancel
the selection.
The following values can be choosen:
ENERGY -
True Energy™
MOTR CURR -
Wire drive motor current
WELD SCOR -
WeldScore™
WFS IPM -
Wire feed speed in inches per minute
WFS MPM -
Wire feed speed in meters per minute
NONE -
disable additional display
Displaying True Energy™
To display True Energy™, select EN ERGY from the ALT DISP
menu.
Every five seconds while welding, the display will show True
Energy™ on the Left DISPLAY with the units on the Right
DISPLAY. The units will change from joules (J), kilojoules (kJ), and
megajoules (MJ), as appropriate.
Displaying Motor Current
To display wire feeder motor current, select MOTR CURR from the
ALT DISP menu.
Every five seconds while welding, the display will show motor
current in amperes on the Left DISPLAY with AMPS on the Right
DISPLAY.
Displaying WeldScore™
To display WeldScore™, select WELD SCOR from the ALT DISP
menu.
Every five seconds while welding, the display will show the instan-
taneous WeldScore™ percentage on the Left DISPLAY and a
percent sign on the Right DISPLAY.
Displaying Wire Feed Speed in Inches per Minute
To display wire feed speed feedback in inches per minute, select
WFS IPM from the ALT DISP menu.
Every five seconds while welding, the display will show the wire
feed speed on the Left DISPLAY and IPM on the Right DISPLAY.
Displaying Wire Feed Speed in Meters per Minute
To display wire feed speed feedback in meters per minute, select
WFS MPM from the ALT DISP menu.
Every five seconds while welding, the display will show the wire
feed speed on the Left DISPLAY and MPM on the Right DISPLAY.
Disabling the Alternative Display
For no alternative display, select NONE from the ALT DISP menu.
While welding, the Left DISPLAY will show welding current in
amperes and the Right DISPLAY will show welding voltage in volts.
ALT
DISP
EN
ERGY
1.32
Kj
MOTR
CURR
2.47
AMPS
WELD
SCOR
97
%
WFS
IPM
IPM
238
WFS
MPM
MPM
6.1
NONE
Summary of Contents for POWER WAVE R450
Page 47: ...F 4 NOTES L16215 A 01 13 94 22 45 27 43 6 00 18 35 24 76 ...
Page 48: ...F 5 NOTES ...
Page 49: ......