Test Meter PC Board Wire Feed Speed Accuracy.
(Metric Models Only)
1. Use a test meter with at least 3-1/2 digits and
± 0.5% accuracy.
2. Connect the + probe to lead called for in the table
below and the - probe to lead #510C.
NOTE: The coating will have to be removed from the
test points.
3. With the meter in SET M/MIN, adjust the speed
control until the LN-9 GMA meter matches the set-
tings in the table below. If the test meter does not
match the readings, the meter PC board may be
faulty. Replace the meter PC board.
TROUBLESHOOTING & REPAIR
F-45
F-45
LN-9 GMA Wire Feeder
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Section TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
Retur
n to Master TOC
METER CIRCUIT ACCURACY TEST
(continued)
METRIC MODEL
METRIC RANGE
SET M/MIN READING
TEST VOLTMETER
READING
LN-9 GMA or LN-9F GMA
LO
8.28
LEAD #560
2.00 ± .05VDC
HI
24.8
LEAD #561
6.00 ± .07VDC