![Lincoln Electric LINC FEED 34 Operator'S Manual Download Page 13](http://html1.mh-extra.com/html/lincoln-electric/linc-feed-34/linc-feed-34_operators-manual_1919128013.webp)
A-8
E. Memory Function - Recalling Memory (LF 35 Only)
Description:
The saved Memory configurations can be recalled.
Set-Up:
While pressing the
Prog
button, rotate the left knob until
"RECALL MEMORY"
appears on the display.
Selection:
Release the
Prog
button, then rotate the left knob to scroll through the saved
memory configurations. Only the memory locations that have been used will be
available. Once selected, begin welding.
Welding:
While welding in Memory Mode, the
Non-Synergic Voltage
or the
Synergic
Trim
values can be varied approximately 5% using the right knob. This allows for
fine adjustment of the welding characteristics.
To Exit:
To return to Non-Synergic or Synergic welding, press the
Prog
button and rotate
the left knob until the proper parameter appears. See sections A and B for further
details.
Memory Screen Example: