B-25
OPERATION
POWER FEED™ 25M NNS
Parameter
Definition
P.82
Voltage Sense Display
AllowsviewingofVoltageSenseLeadSelectiontoaidintroubleshooting.Theconfigurationis
displayedasatextstringonthelowerdisplaywhenevertheoutputisenabled.Thisparameter
isnotsavedonapowercycle,butwillberesettoFalse.
P.99
Show Test Modes
Mostpowersourcescontainweldmodesusedforcalibrationandtestpurposes.Bydefault,the
machine does not include test weld modes in the list of weld modes that are available to the
operator.Tomanuallyselectatestweldmode,setthisoptionto"Yes".Whenthepowersource
isturnedoffandbackonagain,thetestmodeswillnolongerappearinthemodelist.Testweld
modestypicallyrequirethemachineoutputtobeconnectedtoagridloadandcannotbeused
forwelding.
P.100
View Diagnostics
Diagnostics are only used for servicing or troubleshooting the Power Wave system. Select
"Yes" to access the diagnostic options in the menu. Additional parameters will now appear in
thesetupmenu(P.101,P.102,etc).
P.101
View Event Logs
Usedforviewingallthesystemeventlogs.PresstheRightButtontoentertheoption.Rotate
ControlKnobtoselectthedesiredeventlogtoread.PresstheRightButtonagaintoenterthe
selectedlog.RotatingtheControlKnobwillscrollthroughtheeventlog,displayingthelogindex
number,eventcodeandsomeotherdata.PresstheLeftButtontobackouttoselectanother
log.PresstheLeftButtonagaintoexitthisoption.
P.102
View Fatal Logs
Used for viewing all the system fatal logs. Press the Right Button to enter the option. Rotate
ControlKnobtoselectthedesiredfatallogtoread.PresstheRightButtonagaintoenterthat
log.RotatingtheControlKnobwillscrollthroughthelog,displayingthelogindexnumberand
fatalcode.PresstheLeftButtontobackouttoselectanotherlog.PresstheLeftButtonagain
toexitthisoption.
P.103
View Software Version Information
Usedforviewingthesoftwareversionsforeachboardinthesystem.PresstheRightButtonto
enter the option. Rotate Control Knob to select the desired board to read. Press the Right
Buttonagaintoreadthefirmwareversion.PresstheLeftButtontobackouttoselectanother
board. Rotate the Control Knob to select another board, or press the Left Button to exit this
option.
P.104
View Hardware Version Information
Usedforviewingthehardwareversionforeachboardinthesystem.PresstheRightButtonto
enter the option. Rotate Control Knob to select the desired board to read. Press the Right
Buttonagaintoreadthehardwareversion.PresstheLeftButtontobackouttoselectanother
board.PresstheLeftButtonagaintoexitthisoption.
P.105
View Welding Software Information
UsedforviewingtheWeldSetinthePowerSource.PresstheRightButtontoreadtheWeld
Setversion.PresstheLeftButtontobackoutandexitthisoption.
USER DEFINED PARAMETERS