background image

IM3056 

11/2017 

REV01 

LGA Interface 

 
 

OPERATOR’S MANUAL 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

ENGLISH 

 

 

Lincoln Electric Bester Sp. z o.o. 

ul. Jana III Sobieskiego 19A, 58-263 Bielawa, Poland 

www.lincolnelectric.eu 

 

Summary of Contents for K14140-1

Page 1: ...IM3056 11 2017 REV01 LGA Interface OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland www lincolnelectric eu ...

Page 2: ...NET K14140 2 LGA Interface DEVICENET K14140 3 LGA Interface PROFIBUS conforms to the following directives 2014 30 CE and has been designed in compliance with the following standards EN 60974 10 2014 15 11 2017 Piotr Spytek Operations Director Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 263 Bielawa Poland 07 11 ...

Page 3: ...reference record in the table below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDEX Technical Specifications 3 Electromagnetic Compatibility EMC 3 Safety 4 Introduction 5 Installation and Operator Instructions 5 Appendix 18 WEEE 21 Spare Parts 21 Authorized Service Shop...

Page 4: ...e Radio and or television transmitters and receivers Computers or computer controlled equipment Safety and control equipment for industrial processes Equipment for calibration and measurement Personal medical devices like pacemakers and hearing aids Check the electromagnetic immunity for equipment operating in or near the work area The operator must be sure that all equipment in the area is compat...

Page 5: ...tor creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker shall consult their physician before operating this equipment CE COMPLIANCE This equipment complies with the European Community Directives ARTIFICIAL OPTICAL RADIATION According with the requirements in 2006 25 EC Directive and EN 12198 Standard the equipment is a category 2 It...

Page 6: ...s should be backed up first and then restored when the new module board is installed The LGA Interface is designed for ease of configure and use with a PLC There are two modes of operation Job Mode and Job Mode with Parameter Inputs Each of these modes of operation requires that 12 bytes of data be sent to and from the Master to the welder In its simplest implementation Job Mode all that is requir...

Page 7: ...ng Red Green Self Test MS Module Status State Indication Off No Power Green Operating in Normal Condition Flashing Green 1Hz Missing or incomplete configuration device needs commissioning Red Unrecoverable Fault s Flashing Red 1Hz Recoverable Fault s Alternating Red Green Self Test Power Supply The total number of units that can be connected to the DeviceNet bus is limited by the maximum current t...

Page 8: ...have a bending radius of greter than 75mm standard thin cables have a bending radius of greater than 50mm Round shielded cable thick mid and thin contains five wires one twisted pair red and black for 24V dc power one twisted pair blue and white for signal and a drain wire bare Network Topology Understand the Topoly The DeviceNet cable system uses a trunk drop line topology Trunk line Drop Line De...

Page 9: ...ception Error Profibus Connector DB9F Pin Signal Description 1 2 3 B Line Positive RxD TxD RS485 level 4 RTS Request to send 5 GND Bus Ground isolated 6 5V Bus Output 5V termination power isolated short circuit protected 7 8 A Line Negative RxD TxD RS485 level 9 Housing Cable Shield Internally connected to the Anybus protective earth via cable shield filters according to the PROFIBUS standard Cabl...

Page 10: ...ssible errors If a fault occurs the weld Power Wave will turn the output off and welding will not be possible until the problem is corrected and the fault is cleared Wire Stick True value indicates that after the welding output is turned off there is a short between the electrode and the workpiece This will stay true until the welding output is turned on and the error is cleared or if a Touch Sens...

Page 11: ...ther in English Inches per Minute or in Metric CM per Minute The default settings is Metric I O from Master to Welder I O Format while in Job Mode Cyclic I O To Welder From Master Byte B7 B6 B5 B4 B3 B2 B1 B0 0 Control Bit 1 Control Bit 0 Trigger 1 PM Flt Reset Weld Disable Touch Sense CI Rev CI Fwd Gas Purge 2 Job Number low byte 3 Job Number high byte 4 5 6 7 8 Production Monitoring Profile Numb...

Page 12: ...prevent any welding If this is turned on during welding and Enable Burnback on a Fault is true then weld sequencer will transition to the Burnback state and then disable the weld controller preventing any welding If this is turned on during welding and Enable Burnback on a Fault is set to false then the welding will be stopped immediately and the weld controller will be disabled preventing any wel...

Page 13: ...ething like ramping or crater it will still do it If it is desired for the interface to perform these functions then make sure that selected Job is not setup to perform them Note that the Trim and Non Synergic WFS input might not be relevant for all welding modes The Non Synergic WFS is active for Non Synergic wave forms only Note the actual internal units limits and decimal places of the paramete...

Page 14: ...pslope Timer 2 Trigger Off 3 Arc Out Output On Wire On Gas On WELD Steady welding state 1 Trigger Off 2 Arc Out Output On Wire On Gas On DOWNSLOPE Welding parameters are ramped linearly from their steady state welding values to arc ending values 1 Downslope Timer 2 Trigger On 3 Arc Out Output On Wire On Gas On CRATER Allows the welding crater to be filled 1 Crater Timer 2 Trigger On 3 Arc Out Outp...

Page 15: ...o to ReStike Go to Weld 6 Weld If Downslope time go to D S else if Crater time go to Crater else if Burnback time go to BB else if Postflow time go to Postflow else go to Idle Go to ReStike 8 DownSlope Go to Weld if Postflow time go to Postflow else go to Idle if Crater time go to Crater else if Burnback time go to BB else if Postflow time go to Postflow else go to Idle 9 Crater Go to Weld if Post...

Page 16: ...hed too but the interface will continue using the old state timer from the last Job for the current weld Upslope Downslope The time between slope updates is fixed at 100ms and the total slope time will always be rounded off to a 100ms Always one step will be done even if the slope time is less than 100ms The number of slope steps that are done is equal to the slope time divide by 100 with the remi...

Page 17: ...off then the correct solenoid type will be turned on when commanded Setting Feedback Rate Used to set the feedback rate in the Weld Controller for the Current and Voltage and the WFS feedback rate in the Wire Drive This takes effect only after reset If this value is greater than the present setting then no update will be done Enable Wire Stick Check After change this setting the system must be res...

Page 18: ...s the weld state that the machine went too Set WFS Displays the Wire Feed Speed that went to the wire drive Commands Displays when certain items were turned on or off this includes WC Weld Controller Output On WC Output Off Gas On Gas Off WD Wire Drive Motor On WD Motor Off Events Show when some type of event happened Use Power Wave Manager and the Lookup Error section to interpret what the return...

Page 19: ...ult Node Address 5 PROFIBUS requires to configure module parameters with Power Wave Manager Software that You can download from http powerwavesoftware com or with LGA Control Panel ref IM3055 Figure 7 Node Address unique node address 1 125 Maintenance WARNING For any repair operations modifications or maintenance it is recommended to contact the nearest Technical Service Center or Lincoln Electric...

Page 20: ...for any customer s particular purpose with respect to such information or advice As a matter of practical consideration we also cannot assume any responsibility for updating or correcting any such information or advice once it has been given nor does the provision of information or advice create expand or alter any warranty with respect to the sale of our products Lincoln Electric is a responsive ...

Page 21: ...er is not listed Contact the Lincoln Electric Service Department for any code number not listed Use the illustration of assembly page and the table below to determine where the part is located for your particular code machine Use only the parts marked X in the column under the heading number called for in the assembly page indicate a change in this printing First read the Part List reading instruc...

Reviews: