![Lincoln Electric K14138-1 Operator'S Manual Download Page 38](http://html1.mh-extra.com/html/lincoln-electric/k14138-1/k14138-1_operators-manual_1919105038.webp)
English
English
35
Welding GMAW and FCAW-GS Process in synergic mode CV
In synergic mode, the welding voltage is not set by user.
The correct welding voltage will set by the machine’s
software.
This value was recalled on the basis of data (input data)
had been loaded:
Wire Feed Speed, WFS [9].
Table18. Exemplify GMAW and FCAW-GS synergic programs
Wire material
Gas
Wire diameter
0.8
0.9
1.0
1.2
1.4
1.6
Steel CO
2
93
138
10
20
24
-
Steel
ArMIX
94 139 11 21 25 107
Stainless ArCO
2
61 29 31 41 - -
Stainless Ar/He/CO
2
63 - 33 43 - -
Aluminum
AlSi
Ar
- - - 71 - 73
Aluminum
AlMg
Ar
- - 151
75 - 77
Metal
Core
ArMIX
- - - 81 - -
Cored Wire
CO
2
- - - 90 - -
Cored
Wire
ArMIX
- - - 91 - -
Note:
The list of available programs depends on the power source.
If it is needed, the welding voltage can be adjusted
± 10V by the Right Control [10]. When the Right Control
is rotated, the display will show a positive or negative bar
indicates if the voltage is above or below the ideal
voltage.
Preset voltage above
ideal voltage
v
23.5
Preset voltage at
ideal voltage
v
25.9
Preset voltage below
ideal voltage
v
27.8
Additionally can manually set:
Burnback
Run-In WFS
Preflow Time/ Postflow Time
Spot Time
2-Step/4-Step
Crater
Wave Control
Pinch
The 2-Step - 4-Step
changes the function of the gun’s
trigger.
2 Step trigger operation turns welding on and off in
direct response to the trigger. Welding process is
performed when the gun’s trigger is pulled.
4-Step mode allows to continue welding, when the
gun’s trigger is released. To stop welding, the gun’s
trigger is pulled again. 4-step mode facilitates to
making long welds.
Note:
4-Step does not work during Spot Welding.
Figure 73
Pinch
controls the arc characteristics when short-arc
welding. Increasing Pinch Control greater than 0.0
results in a crisper arc (more spatter) while decreasing
the Pinch Control to less than 0.0 provides a softer arc
(less spatter).
Adjust range: from -10 to +10.
Factory default, Pinch is OFF.
M
-10.0
10.0
OFF
OFF